I will keep this in mind, I have not had this issue before because disabling that feature has always worked for me. Thanks
toggle quoted message
Show quoted text
--- In Crestron@..., Richard Cronk <rcronk@...> wrote:
I didn't even wair for the strings all I did was send the two carriage
returns before I sent the actual command
On 2013-06-01 6:52 PM, "avsystemdesign" <avsystemdesign@...> wrote:
**
Thank you Richard and Chip!
So I should have an SIO with the expected query strings from the Sharp
display, example "username:" on line 1 & "password:" on line 2. When the
SIO see's that, it then transmits "\x0D" on both occasions?
This will then allow connection and I should be able to shoot commands at
the display?
It makes sense to me, thanks again guys!
--- In Crestron@..., Richard Cronk <rcronk@> wrote:
I just programed one. All you do is send a \x0d for each . Then you send
the command
On 2013-05-31 8:04 PM, "avsystemdesign" <avsystemdesign@> wrote:
**
Hey guys, I am trying to control a Sharp TV over Ethernet. The problem
is
it requests a password. Is there a way to disable this? Or do I need
to do
something in the program to fulfill its request?
When I connect to the display with my web browser, it also asks for a
username and password, yet there is no user name or password, so simply
hitting OK lets you in.
Thanks in advance.
[Non-text portions of this message have been removed]