I don't recognize the model number, but if it has a DB9, look in the manual and see if it makes any mention of "MDC" or "Multiple Display Control", in which case it does NOT use the EX-link.
For MDC, the 400/460 module in I2P will get you started, but you're best off just copying the SIO and checksum generator from that module and pasting it into your own code.
- Chip
toggle quoted message
Show quoted text
--- In Crestron@..., "ChrisK" <chris@...> wrote:
Hi All,
Has anyone integrated one of the new Samsung plasmas, like the PN(xx)F8500AF? Specs say 'RS232' in stead of Ex-link. If so:
1. is it a real DB9 connector?
2. does it use the Ex-link Protocol? (I searched for a doc, and have a call in to my rep...)
3. does it have commands for custom picture memories?
IF I get a doc I will post...
TIA,