I had a CP3 that failed a firmware update and the IR board had an
incompatible firmware version and thus would not output IR. Had to call
Crestron and after attempting to flash the firmware for 45 minutes they
RMAd it.
On Tue, May 21, 2013 at 3:30 PM, Russell Grove <russellrgrove@...>wrote:
**
I had this problem with an Adagio a few years ago. I had a bad IR file
that worked fine in a PRO2 but when specific buttons were pressed it would
lock up the Adagio until power cycled.
-Russell
Sent from my iPhone
On May 21, 2013, at 4:03 PM, "Jon W" <jonwaldrip@...> wrote:
I have a CP3 that has had a problem twice now, where all 8 IR ports
simply stop outputting anything. Everything seems fine (ethernet, serial,
relays, etc�) when it happens.
From debugger I can see no signal being held high, and I can pulse
signals on different ports, but the signals do not reach the emitters.
I am also getting an error log full of this error:
Error: TLDM.exe # 03:23:51 5-22-2013 # S3 IOP error: Queueing IR packet
failed
Power cycling fixes the issue.
Tech support had never heard of it this morning.
Anyone else ever experience anything like that?
-Jon
[Non-text portions of this message have been removed]
[Non-text portions of this message have been removed]