Re: Activity Detection


Chip
 

If there isn't a device extender for it, your only choice is to have the panel on Ethernet, open a TCP/IP client connection to it and send the command that way...

- Chip

--- In Crestron@..., "Kol Johnson" <kol.mstc@...> wrote:

can we check and turn that off from within simpl? It would be nice to add
that so if a panel got replaced the program would turn that off. Then I
could remove the PAGEJOINXMIT sticker from the top of my laptop screen ;)


_____

From: Crestron@... [mailto:Crestron@...] On Behalf
Of Gregg M
Sent: Friday, May 10, 2013 12:19 PM
To: Crestron@...
Subject: [Crestron] Re: Activity Detection




It was the Page Join Transmit.....always the little things

Thanks

--- In Crestron@... <mailto:Crestron%40yahoogroups.com> ,
Lincoln King-Cliby <lincoln@> wrote:

And on that note, if you don't need the page join feedback you can turn
off Page Join Feedback Transmission (without connecting to a panel
PAGEJOINXMIT ?) -- I'd say that's certainly not helping because the
processor sees it as inbound data from the panel and thus "activity"

Lincoln

--
Lincoln King-Cliby, CTS
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
V: 440.449.1100 x1107 | F: 440.449.1106 | I:
Crestron Services Provider


-----Original Message-----
From: Crestron@... <mailto:Crestron%40yahoogroups.com>
[mailto:Crestron@... <mailto:Crestron%40yahoogroups.com> ] On
Behalf Of Jay Basen
Sent: Friday, May 10, 2013 2:27 PM
To: Crestron@... <mailto:Crestron%40yahoogroups.com>
Subject: Re: [Crestron] Activity Detection

I expect this may be due to page joins transmitting back from the touch
panel to the processor.

Hope this helps

Jay

----- Original Message -----

From: "Gregg M" <jets_in_2003@>
To: Crestron@... <mailto:Crestron%40yahoogroups.com>
Sent: Friday, May 10, 2013 9:23:58 AM
Subject: [Crestron] Activity Detection





So I have a small piece of code running in my MC3 that basically says if
my TPS-4L Activity Detection goes Low Set the hard button Backlight to Low
and Jump to Page X. From my understanding Activity Detection is based on
anything from the touch panel to the processor, not the other way around.
But in my case here, when the processor triggers the page flip, it also
registers that as activity, thus trigger the backlights to go high and the
timer to restart.

Am I incorrect in my assumption or am I just plain doing something wrong.





[Non-text portions of this message have been removed]



------------------------------------

*
****