Thanks for all replies. Sorry just got a chance again to play with this upgrade. I have following SW & FW VERs in the system
AV2: 4.007.0004
IMPL Windows: 4.02.08
SIMPL+ 4.02.07
Path: C:\Program Files\Crestron\Simpl
INCLUDE4_2SERIES.DAT Version Information:
(2 Series) : 1.79
INCLUDE4.DAT Version Information:
(3 Series) : 1.14.017
Data Files:
Path: C:\Program Files\Crestron\Cresdb\Programming
symlib.tio 855 03/07/2013 05:34:02PM
iodev.tio 855 03/07/2013 05:34:02PM
Other Crestron SW:
Device Database: 48.05.005.00
Crestron Database: 38.00.006.00
Crestron Toolbox: 2.35.239.03
SIMPL+ Cross Compiler: 1.3
I have initialized the processor, re-flashed the firmware but the issue still pertains. Anything you guys see wrong with these firmware versions or any other possibilities?
TIA
toggle quoted message
Show quoted text
--- In Crestron@..., "h" <web1111a@...> wrote:
Actually,
There was a database release that had an include.dat that caused 3.155 firmware to continually reboot
Harvey
--- In Crestron@..., "Chip" <cfm@> wrote:
D'oh - you're right...
- Chip
--- In Crestron@..., "Ted" <ted_brincka@> wrote:
Actually, it's the reverse. If you update the firmware without recompiling the program with the newer databases then you get the problem.
--- In Crestron@..., "Chip" <cfm@> wrote:
Any chance the firmware in the unit is kinda on the old side? A few database versions back I found that newly compiled programs would stop working in processors they had been fine in until the firmware got uppped.
- Chip
--- In Crestron@..., "coolaiddrinker" <coolaiddrinker@> wrote:
Hi Guys,
When I load new program in the processor, it keeps rebooting. I can get it back by bypassing the program and reloading the old one.
Any clue what should I be looking for in the program that may cause this? I only Biamp and Tandberg Modules in the program. rest are just buffers so I can run non core 3 on tp and test core 3 on xpanel and provide feedback to smart objects..
TIA