Re: Creating Epson serial module for Powerlite G5450


 

I am only polling Power, Source, Mute, Lamp Hours. I was getting the ERR back even when I was only polling Power

--- In Crestron@..., "matt_rasmussen_2000" <mjrtoo@...> wrote:

If I take the time to create a module for a specific projector, I would stop polling for everything but power status when it's off.


--- In Crestron@..., "chuckperkinscrestron" <chuckperkinscrestron@> wrote:

I have created a module for our Epson G5450 projectors. Everything seems to work but I have a couple questions.

1. When the projector is "Off", I get a ERR&#92;x0D when polling the projector, I will get the PWR=04&#92;x0D also, that shows that it's off. When the projector is "On" I only receive the PWR=01&#92;x0D response from the projector. I have the module set to pulse the "Proj is On" or the "Projector Is Off" based on the status returned from the polling. With this polling, my touch panel buttons are always in sync with the status of the projector On/Warmup/CoolDn/Off even if the projector in control by the IR remote. I see in the Crestron Module for the Epson G5650 (which uses the same commands) that they watch for the ERR or : (ack) but I can't figure out what they are doing when the response is received.

I created my own module so that I can monitor/control just what I need - Power On/Off, Pic Mute On/Off, Lamp Hours, Select HDMI Input

Does the ERR&#92;x0D response cause issues after polling for long periods of time?

2. I have noticed that after the projector has been Off over night, that it doesn't respond to the Power On command from the button press. After the first time the power on press makes the projector turn on almost immediately. I don't see any shut down/sleep timers that are set in the projector.

Thanks for any info you maybe able to share.
Chuck