The control ID may be referring to a Smart Object ID and not a ccross id. Check the Smart Object extenders under the xPanel symbol. You will probably find a couple that are set to 0d.
That would mean that you probably didn't set the Smart Object IDs for some of your smart objects, in VTPro, before importing the CED files into Simpl Windows...
toggle quoted message
Show quoted text
--- In Crestron@..., "af8567" <af8567@...> wrote:
Using layered crosspoints
750 to office lights. All works correctly. I add a core 3 xpanel in the same fashion as with the 750. Create unique signal names and control id on the ccross for the xpanel lighting. When I compile I get an error that the xpanel symbol contains duplicate control joins =0d.I can't find where I have any duplicate control joins. Moreover all of my control joins in the entire project are 500+. So I can't see where the 0d could even come in. Any thoughts? Thanks in advance