Re: Crestron - Ipad ... Analog Value ... & Error Log ...


Chip
 

Yep - ditch that and the (IIRC) the TCP/IP client symbols that it's attached to.

In configure view in SIMPL Windows, double-click on your Ethernet slot, and select "Crestron Mobile" from the menu that comes up.

- Chip

--- In Crestron@..., "steex_777" <steex@...> wrote:



Hi Chip,

I'm using the CRESTRON IPHONE AND IPOD TOUCH INTERFACE V2.0 (cm)

Is there an another one to use ?

Where is it located in the symbol library ?

Many thanks, This will help a lot...

³§³Ù¨¦±è³ó²¹²Ô±ð


--- In Crestron@..., "Chip" <cfm@> wrote:


Ditch the iPhone/iPad interface modules you're using and use the Crestron Mobile native symbol instead...

- Chip


--- In Crestron@..., "steex_777" <steex@> wrote:

Hi guys,

I'm using 2 Ipads in a system where i have a PRO2 and a QM-RMC inter-connected...

I'm getting those messages in the error log from the processor :

67. Error: Module S-2.2:S-1 : S2_iPhone_XML_Processor_v1_0_0 at line 155: Output Array __XML2ANA overflow. Index = 27198. Bounds = 999
TimeStamp: 13:10:28 1-02-13 UpTime: 0 days 00:33:34.61 Task: S005002
68. Error: Module S-2.2:S-1 : S2_iPhone_XML_Processor_v1_0_0 at line 160: Output Array __XML2DIG overflow. Index = 27300. Bounds = 1999
TimeStamp: 13:10:28 1-02-13 UpTime: 0 days 00:33:34.81 Task: S005002

From what i've seen so far, it's inside a SIMPL+ module inside the IPHONE IPOD TOUCH symbol...

Since i'm using the iphone/ipod touch symbol... there is no way (in my opinion) i can be over 2000 dig signals and 1000 analog signals...

From what i've dug so far

Turns out that you can only use the Analog IN/OUT for animation purposes...

(TB : 4874)

5) To manually enter Signal Names, select the " + " sign next to the Digitals, Analogs or Serials directly on the [iPhone and iPod Touch interface] module.
Note: Analog values are supported for Animated objects only. See below under Issues Found and Reported for a work around if needing to send an Analog value.

Now I'm curious about the need for 1000 analog join number to do 1000 animations...

I was using some analog join to send/receive Temp, dvr channel number, volume bar level, and animations...

I've commented out those analog values and left only the analog value for 1 or 2 animation (only 90 frames - it's for channel icons)

But i still got the same error in the pro2 logs...

Anyone any ideas ?

Thanks

³§³Ù¨¦±è³ó²¹²Ô±ð