After a little detective work, I found several problems with the module. The oscillator was causing resets every three seconds after the time specified in the modifier. There was also a serial gather that completely prevented the feedback from populating.

I have edited it to work for the Pentair, but I won't test it with Jandy because I strongly oppose their products. I'll upload when I confirm that it works.

-L

--- In Crestron@..., "pacomom" <pacomom@...> wrote:

Yeah. There is actually an oscillator in the module that seems to be causing a problem. I commented out the TOD and added my own When symbol for a manual reset.

--- In Crestron@..., "nholmes80" <nholmes1@> wrote:

Has anyone else had a problem with this module continually sending the reset command #RST? I am not holding any logic high, I am using a qm-rmc to provide a remote RS-232 port and it has the pentair i-Link adapter connected to port-A. I am just trying to test through simpl debugger and noticed the TX$ of the module sending #RST&#92;x0D every second or so.



--- In Crestron@..., "Kol Johnson" <kol.mstc@> wrote:

There is one in the files area, you may need to check the delimiter or the
command character depending on which firmware is in the adapter.



_____

From: Crestron@... [mailto:Crestron@...] On Behalf
Of donerbe
Sent: Thursday, January 19, 2012 11:15 AM
To: Crestron@...
Subject: [Crestron] Pentair Pool Controller




Does anyone have a module or the rs-232 codes to control a pentair pool
controller?