Should be GETD, and the label applies to the instance ID not a specific IO of the block. So instead of instance ID 21 you would type Master in the instance ID field. You have to use the real values for the index1/2.
toggle quoted message
Show quoted text
--- In Crestron@..., "mudzone2000" <mudzone2000@...> wrote:
added biamp to system, serial control, cable is correct. when commands go out to audia it returns "command not recognized" from device. I am sending GET D 1 OUTLVL 21 . I am not sure about the addressing of controls within audia, when i look at audia prperty sheet for this control, it is labeled Control2, with DSP attributes 1 listed as:
allocated to unit 1
instance id 21
level label master
so in module I chose to label it
I/O output level
volume deve=ice id 1
volume device instance 21
volume index1 master
volume index2 0
where am i going wrong?