Re: I'm Loosing It...


Simon Cope
 

Yup. Your gateway is screwed. I used to see this reasonably frequently a
few years back - you'll need to send the GW back for repair/replacement.

Simon C

2010/1/21 Lincoln King-Cliby <lincoln@...>



My system at home: I replaced a C2N-CBD with a CNX-BF12. Existing wire,
didn't even change the Phoenix connectors. Now all of a sudden the
ML-500/600s on the CNRFGWA-418 stop chatting.

Disconnect CNX-BF12 Cresnet at the CNT-BLOCK end of the cable... no change.
Even with an ML-500 at 6", 18", and 3'.

Take antenna off CNRFGWA-418 and the ML-500 works within about 3' of the
gateway. Put antenna back on, goes back to not working.

An interesting observation is that the "SIGNAL" LED on the 433 CNRFGWA
right next to the -418 is clearly illuminated with I hit any button; the
"SIGNAL" LED on the -418 only flashes when I take the antenna off or
physically touch the ML-500 to the -418's antenna (in that case, though,
even though the signal usually LED comes on nothing seems to happen)

Making me scratch my head even more: Using Superdebugger is showing me
"something" being received by the gateway, but that's not triggering the
logic associated with the press in the program

E.g. press and release "Prev Ch" on the remote that should be RFID 20
<01/21/2010 14:17:03>CRX:Slot-01.ID-73 :1 Way TX ID:6F Join:33 Value:1
<01/21/2010 14:17:03>CRX:Slot-01.ID-73 :1 Way TX ID:00 Join:0 Value:0

Press and release softkey 10 for group 1
<01/21/2010 14:19:01>CRX:Slot-01.ID-73 :1 Way TX ID:49 Join:34 Value:1
<01/21/2010 14:19:01>CRX:Slot-01.ID-73 :1 Way TX ID:00 Join:0 Value:0

Any ideas?

Lincoln

--

Lincoln King-Cliby, CTS
Applications Engineer
ControlWorks Consulting, LLC

V: 440.449.1100 x1107 F: 440.449.1106 I:
Crestron Authorized Independent Programmer





[Non-text portions of this message have been removed]