Re: 6pack in bpq ?

 

This can be done with bpqkiss also.. works great,did run 3 tiny-2 this way on one com port.

Op 17 jul. 2024 04:33 schreef "Chris K1MAL via groups.io" <radiochris@...>:

I uploaded the linux source code for the driver, and (the translated) web pages from the old German flexnet site in case anyone wants to take it on.?
I found it in archive.org's wayback machine. I also included the 6pack eprom in the zip file.
?
/g/bpq32/files/6pack_info.zip
?
I think the coolest thing about 6pack is the way you can daisy chain TNC's via just their RS232's TX and RX's together in series like a token ring network. Doing this lets lets you run multiple TNC's on one rs232 PC port.?
?
73
Chris K1MAL


Re: 6pack in bpq ?

 

I uploaded the linux source code for the driver, and (the translated) web pages from the old German flexnet site in case anyone wants to take it on.?
I found it in archive.org's wayback machine. I also included the 6pack eprom in the zip file.
?
/g/bpq32/files/6pack_info.zip
?
I think the coolest thing about 6pack is the way you can daisy chain TNC's via just their RS232's TX and RX's together in series like a token ring network. Doing this lets lets you run multiple TNC's on one rs232 PC port.?
?
73
Chris K1MAL


Re: RMS with ARDOP

 

I found the problem. Wrong ARDOP_WIN version. I used in BPQ32 the 0.9.0.0 version from ARDOP CHAT. Changing for the 1.0.2.6 version that comes with Winlink Express works fine.? :-)))

Thanks for the help, John and Mark. My Best regards. ?:-)

Em ter., 16 de jul. de 2024 ¨¤s 05:28, John G8BPQ via <john.wiseman=[email protected]> escreveu:

I loaded your config here and it works ok.

The call to PY1XTA-10 connects to the CMS but fails to login as the
password isn't set.

The call to PY1XTA connects to the node. I don't get any ctext as you
haven't defined HFCTEXT in your config, but I can enter node commands.

So I'm puzzled as to why it doesn't work for you.

73,
John

*** ARQ Call to PY1XTA-10 (Bandwidth = 500MAX) @ 2024/07/16 08:22:51
??*** ARDOP_Win TNC STATUS:? BREAK RECEIVED FROM PROTOCOL STATE IDLE,
NEW STATE IRS @ 2024/07/16 08:23:01
*** G8BPQ Connected to CMS
*** [1] Invalid gateway login - Incorrect password - Disconnecting
(212.56.108.143)
??*** ARDOP_Win TNC STATUS:? ARQ CONNECTION ENDED WITH PY1XTA-10
ID:PY1XTA-10 [GG87ea]:
*** Clear channel detected

*** ARQ Call to PY1XTA (Bandwidth = 500MAX) @ 2024/07/16 08:23:23

G8BPQ[]: ?
??*** ARDOP_Win TNC STATUS:? BREAK RECEIVED FROM PROTOCOL STATE IDLE,
NEW STATE IRS @ 2024/07/16 08:23:44
XTANOD:PY1XTA-4} BBS CHAT RMS CONNECT BYE INFO NODES PORTS ROUTES USERS
MHEARD

G8BPQ[]: rms
??*** ARDOP_Win TNC STATUS:? QUEUE BREAK NEW PROTOCOL STATE IRSTOISS @
2024/07/16 08:24:32
??*** ARDOP_Win TNC STATUS:? BREAK RECEIVED FROM PROTOCOL STATE IDLE,
NEW STATE IRS @ 2024/07/16 08:24:41
Trying
*** G8BPQ Connected to CMS
*** [1] Invalid gateway login - Incorrect password - Disconnecting
(212.56.108.143)
??*** ARDOP_Win TNC STATUS:? ARQ CONNECTION ENDED WITH PY1XTA


On 15/07/2024 21:26, Mauro Veiga wrote:
> My .cfg.
>
> ; Written by BPQConfigGen






Re: RMS with ARDOP

 

I also don't understand what happens. It should work. Perhaps it is in configuration of the ARDOP TNC used in the BPQ32. This is my ARDOP setup and BPQ Windows.

Em ter., 16 de jul. de 2024 ¨¤s 05:28, John G8BPQ via <john.wiseman=[email protected]> escreveu:

I loaded your config here and it works ok.

The call to PY1XTA-10 connects to the CMS but fails to login as the
password isn't set.

The call to PY1XTA connects to the node. I don't get any ctext as you
haven't defined HFCTEXT in your config, but I can enter node commands.

So I'm puzzled as to why it doesn't work for you.

73,
John


Re: RMS with ARDOP

 

I loaded your config here and it works ok.

The call to PY1XTA-10 connects to the CMS but fails to login as the password isn't set.

The call to PY1XTA connects to the node. I don't get any ctext as you haven't defined HFCTEXT in your config, but I can enter node commands.

So I'm puzzled as to why it doesn't work for you.

73,
John

*** ARQ Call to PY1XTA-10 (Bandwidth = 500MAX) @ 2024/07/16 08:22:51
?*** ARDOP_Win TNC STATUS:? BREAK RECEIVED FROM PROTOCOL STATE IDLE, NEW STATE IRS @ 2024/07/16 08:23:01
*** G8BPQ Connected to CMS
*** [1] Invalid gateway login - Incorrect password - Disconnecting (212.56.108.143)
?*** ARDOP_Win TNC STATUS:? ARQ CONNECTION ENDED WITH PY1XTA-10
ID:PY1XTA-10 [GG87ea]:
*** Clear channel detected

*** ARQ Call to PY1XTA (Bandwidth = 500MAX) @ 2024/07/16 08:23:23

G8BPQ[]: ?
?*** ARDOP_Win TNC STATUS:? BREAK RECEIVED FROM PROTOCOL STATE IDLE, NEW STATE IRS @ 2024/07/16 08:23:44
XTANOD:PY1XTA-4} BBS CHAT RMS CONNECT BYE INFO NODES PORTS ROUTES USERS MHEARD

G8BPQ[]: rms
?*** ARDOP_Win TNC STATUS:? QUEUE BREAK NEW PROTOCOL STATE IRSTOISS @ 2024/07/16 08:24:32
?*** ARDOP_Win TNC STATUS:? BREAK RECEIVED FROM PROTOCOL STATE IDLE, NEW STATE IRS @ 2024/07/16 08:24:41
Trying ec2-54-204-42-249.compute-1.amazonaws.com
*** G8BPQ Connected to CMS
*** [1] Invalid gateway login - Incorrect password - Disconnecting (212.56.108.143)
?*** ARDOP_Win TNC STATUS:? ARQ CONNECTION ENDED WITH PY1XTA

On 15/07/2024 21:26, Mauro Veiga wrote:
My .cfg.

; Written by BPQConfigGen


VARA Port In Use?

 

When forwarding with VARA HF and when there is a message to be send.?If?the freq that
I change to is busy VARA will not let BPQ send the connect command which I understand but?more often than not the VARA port will show as busy and?BPQ will not allow the radio to?
return to its?normal freq.?

Is there a command that will clear the VARA?port?in use?after a period of time??

--?
73 de Glenn N3MEL
(FRNPA) 1st Responders Network of Pa
PKT:145.090 & VARA HF:3.596 WL2K:145.670
Emergency Coordinator
Chester County ARES/RACES

AREDN Mesh: n3mel-hapac-wbrad
Mesh Email:?
n3mel@...



Re: RMS with ARDOP

 

My .cfg.

; Written by BPQConfigGen

SIMPLE
NODECALL=PY1XTA-4
NODEALIAS=XTANOD
LOCATOR=GG87EA

IDMSG: ; UI broadcast text from NODECALL to fixed dest ID
PY1XTA BPQ BBS NODE (IDMSG)
*** ; Denotes end of IDMSG text
BTEXT: ; UI broadcast text from BCALL to destination UNPROTO=
!2258.72S/04339.62W {BPQ32}
PY1XTA BPQ NODE/BBS Test (BTEXT)
*** ; Denotes end of BTEXT text
MAPCOMMENT=PY1XTA BPQ Packet NODE/BBS<BR>Rio de Janeiro - Brazil<BR>7.040MHz USB at 300 Baud<BR>XTANOD:PY1XTA NODE<BR>XTABBS:PY1XTA-1 BBS
INFOMSG: ; The INFO command text follows:
- (INFOMSG)
?.--------------------------------------.
?| ? ?PY1XTA XTANOD TERMINAL BPQ32 ? ? ?|
?| ?Rio de Janeiro, RJ - Brasil - GG87 ?|
?| ? ? ? ?maurorveiga@... ? ? ? ? |
?'--------------------------------------'
PY1XTA-4> CONNECT BYE INFO NODES ROUTES PORTS USERS MHEARD

*** ; Denotes end of INFOMSG text
CTEXT: ; The CTEXT text follows:
-=[ Bem vindo a meu NODE/BBS Experimental ]=- (CTEXT)
?PY1XTA-4> CONNECT BYE INFO NODES ROUTES PORTS USERS MHEARD
*** ; Denotes end of CTEXT text
FULL_CTEXT=1 ; 0=send CTEXT to L2 connects to NODEALIAS only
; 1=send CTEXT to all connectees

; Network System Parameters:
OBSINIT=6 ; Initial obsolescence set when a node is included
; in a received nodes broadcast. This value is then
; decremented by 1 every NODESINTERVAL.
OBSMIN=4 ; When the obsolescence of a node falls below this
; value that node's information is not included in
; a subsequent nodes broadcast.
NODESINTERVAL=20 ; Nodes broadcast interval in minutes
IDINTERVAL=20 ; 'IDMSG' UI broadcast interval in minutes, 0=OF
BTINTERVAL=20 ; The BTEXT broadcast interval in minutes, 0=OFF
L3TIMETOLIVE=25 ; Max L3 hops
L4RETRIES=6 ; Level 4 retry count
L4TIMEOUT=60 ; Level 4 timeout in seconds s/b > FRACK x RETRIES
L4DELAY=10 ; Level 4 delayed ack timer in seconds
L4WINDOW=4 ; Level 4 window size
MAXLINKS=63 ; Max level 2 links
MAXNODES=512 ; Max nodes in nodes table
MAXROUTES=64 ; Max adjacent nodes
MAXCIRCUITS=128 ; Max L4 circuits
MINQUAL=168 ; Minimum quality to add to nodes table
MAXHOPS=4 ; INP3 hop limit to add to tables
MAXRTT=90 ; INP3 max RTT in seconds
;BUFFERS=255 ; This parameter is no longer used in the Win32 version.
; TNC default parameters:
PACLEN=120 ; Max packet size (236 max for net/rom)
TRANSDELAY=1 ; Transparent node send delay in seconds
SAVEMH=1
T3=120 ; Link validation timer in seconds
IDLETIME=720 ; Idle link shutdown timer in seconds

; Configuration Options:
AUTOSAVE=1 ; Saves BPQNODES.dat upon program exit
BBS=1 ; 1 = BBS support included, 0 = No BBS support
NODE=1 ; Include switch support
HIDENODES=1 ; If set to 1, nodes beginning with a #
; require a 'N *' command to be displayed.
/*
The *** LINKED command is intended for use by gateway software, and concern
has been expressed that it could be misused. It is recommended that it be
disabled (=N) if unneeded.
*/
ENABLE_LINKED=N ; Controls processing of *** LINKED command
; Y = allows unrestricted use
; A = allows use by application program
; N = disabled
ROUTES: ; Locked routes (31 maximum)
?;There are no locked routes in this example.
*** ; Denotes end of locked routes

?;RADIO 1 HAMLIB
?
PORT
?PORTNUM=1 ; Optonal but sets port number if stated
?ID=LOOPBACK ; Defines the Loopback port name
?TYPE=INTERNAL ; Loopback is an internal type
ENDPORT

PORT
?PORTNUM=2
?ID=AFSK Ch 1 300 Baud
?TYPE=ASYNC
?PROTOCOL=KISS
?KISSOPTIONS=ACKMODE
?IPADDR=127.0.0.1
?TCPPORT=7100
?CHANNEL=A
?PACLEN=60
?TXDELAY=500
?TXTAIL=30
?FRACK=7000
?RESPTIME=3000
?MAXFRAME=1
?RETRIES=10
?SLOTTIME=100
?PERSIST=64
?PORTCALL=PY1XTA
ENDPORT

PORT
?PORTNUM=4
?ID=VARA HF
?DRIVER=VARA
?PORTCALL=PY1XTA
?INTERLOCK=1
?CONFIG
? ADDR 127.0.0.1 9300
? BW2300
? ;WL2KREPORT PUBLIC, , 80, PY1XTA-10, GG87EA, 19-21, 7041500, VARA, 25
ENDPORT

PORT
PORTNUM=5
?ID=Telnet Server
?DRIVER=TELNET
?CONFIG
? LOGGING=1
? TCPPORT=8010
? FBBPORT=8011
? HTTPPORT=8080
? USER=PY1XTA,202427,PY1XTA,,SYSOP
? USER=ANON,ax25
? LOCALNET=192.168.1.106
? CTEXT=CONNECTED>
? CMS=1
? CMSCALL=PY1XTA-10
? CMSPASS=
? RELAYAPPL=RMS
ENDPORT

PORT
?PORTNUM=7
?ID=ARDOP
?DRIVER=ARDOP
?PORTCALL=PY1XTA
?INTERLOCK=1
?CONFIG
? ADDR 127.0.0.1 9515 ;custom port
? DEBUGLOG TRUE
? CMDTRACE TRUE
? CWID FALSE
? DRIVELEVEL 100
? BUSYWAIT 20
? MAXCONREQ 10
? GRIDSQUARE GG87EA
? FECREPEATS 0
ENDPORT


AGWPORT=8001
AGWMASK=0X30
AGWSESSIONS=2

; Applications
APPLICATION 1,BBS,,PY1XTA-1,XTABBS,255
APPLICATION 2,CHAT,,PY1XTA-2,XTACHA,255
APPLICATION 3,RMS,C 5 CMS,PY1XTA-10,XTARMS,255

; ------------------------------------------------------------------------------
; APRS SETTINGS

APRSDIGI
LOCALTIME=1
DISTKM=1

?APRSCall=PY1XTA
?StatusMsg= BPQ NODE BBS IGATE Experimental 7.040MHz - Vida Longa e Prospera
?; Symbol=& ; Icon, a Black Diamond, to display for station.
?; Symset=I ; This is a "I" in a Black Diamond.
?Symbol=a ; Icon to display for station.
?Symset=B ; This is a "B" in a Red Diamond.
?;
?;APRSPath 1= ;Receive only port
?APRSPath 1=APRS ;Send beacon locally
?;APRSPath 2=APRS,WIDE1-1,WIDE2-1
?APRSPath 2=APRS,WIDE1-1 ;Dest and up to 8 digis
?BeaconInterval=30 ;Send Beacon every 30 minute. Minimum is 5 mins
?BeacontoIS=1
?MAXAGE=120 ;In minutes, after which the APRSCall is 'old'
?Digimap 2=2,IS
?;Digimap 3=3,IS
?;Digimap 4=4,IS
?DIGICALLS=PY1XTA-15
?TraceCalls=WIDE,TRACE ; Calls for CALLN-n Processing with Trace
?ReplaceDigiCalls ; Replace DigiCalls with APRSCall. Omit if you want the call to be left as
; it is received.
?MaxTraceHops=2 ; Max value of n in CALLN-n processing. If a packet is received with n greater than
?MaxFloodHops=2 ; this, the value will be replaced BEFORE it is decremented.
?GPSPort=0 ; if specified, lat/lon will be taken from a GPS
?GPSSpeed=0

; You can specify a fixed LAT/LONG instead of using GPS
?LAT=2258.72S ; Must be in standard APRS Format (ddmm.mmN/S)
?LON=04339.62W ; Must be in standard APRS Format (dddmm.mmE/W)

?ISHost= ; APRS-IS Host Name. May be either an IPV4 or an IPV6 Host
?ISPort=14580 ; Normal port for a filtered feed
?ISPasscode= ; If you don't already have a passcode G8BPQ can issue you one.
?LOGAPRSIS=1

?ISFilter=m/200 u/APBPQ* ; Used in BPQAPRS mapping application as a default to add BPQ nodes wordwide.
; ; Adding this now when there are so many BPQ nodes increases network traffic
; unnecessarily!

*** ;Denotes end of APRSDIGI configuration

ROUTES: ; Locked routes (31 maximum)
*** ; Denotes end of locked routes

Em seg., 15 de jul. de 2024 ¨¤s 17:04, John G8BPQ via <john.wiseman=[email protected]> escreveu:

The ARDOP config you posted doesn't have a PORTCALL.

Maybe it would help if you post your whole config, less any passwords.

73,
John
groups.io> escreveu:
Can you explain what you mean by doesn't work?

What happens when you try to connect? Does the ARDOP console show packets being received? Does the node respond, but fail to establish a connection? Do you get to the node, but not to the RMS application?

73,
John



On 14/07/2024 20:58, Mauro Veiga wrote:
Hi folks. My Winlink Gateway works fine with Packet and VARA HF but not with ARDOP. Is possible to setup BPQ32 to work RMS with ARDOP?

TIA




Re: RMS with ARDOP

 

¿ªÔÆÌåÓý

The ARDOP config you posted doesn't have a PORTCALL.

Maybe it would help if you post your whole config, less any passwords.

73,
John

On 15/07/2024 20:08, Mauro Veiga wrote:

Hello John. I have "Send Kbrd Text to OB Queue On" set to CR and ARQ mode. The port only accept connection to PORTCALL and BPQ not respond to commands typed on ARDOP CHAT.

Em seg., 15 de jul. de 2024 ¨¤s 14:12, John G8BPQ via <john.wiseman=[email protected]> escreveu:
I assume you are using ARQ mode in ARDOP Chat. I tested with "Send Kbrd Text to OB Queue On" set to CR in the ARDOP Chat Setup and it seems to work fine here. Are you calling the Node Call-SSID or the RMS application Call/SSID?

73,
John


On 15/07/2024 17:23, Mauro Veiga wrote:
The ARDOP port accept conection from The ARDOP CHAT for example. But any commands like Help, Info, BBS or RMS are not passed to BPQ.

Em seg., 15 de jul. de 2024, 12:08, John G8BPQ via <john.wiseman=[email protected]> escreveu:
Can you explain what you mean by doesn't work?

What happens when you try to connect? Does the ARDOP console show packets being received? Does the node respond, but fail to establish a connection? Do you get to the node, but not to the RMS application?

73,
John



On 14/07/2024 20:58, Mauro Veiga wrote:
Hi folks. My Winlink Gateway works fine with Packet and VARA HF but not with ARDOP. Is possible to setup BPQ32 to work RMS with ARDOP?

TIA




Re: RMS with ARDOP

 

Hello John. I have "Send Kbrd Text to OB Queue On" set to CR and ARQ mode. The port only accept connection to PORTCALL and BPQ not respond to commands typed on ARDOP CHAT.

Em seg., 15 de jul. de 2024 ¨¤s 14:12, John G8BPQ via <john.wiseman=[email protected]> escreveu:

I assume you are using ARQ mode in ARDOP Chat. I tested with "Send Kbrd Text to OB Queue On" set to CR in the ARDOP Chat Setup and it seems to work fine here. Are you calling the Node Call-SSID or the RMS application Call/SSID?

73,
John


On 15/07/2024 17:23, Mauro Veiga wrote:
The ARDOP port accept conection from The ARDOP CHAT for example. But any commands like Help, Info, BBS or RMS are not passed to BPQ.

Em seg., 15 de jul. de 2024, 12:08, John G8BPQ via <john.wiseman=[email protected]> escreveu:
Can you explain what you mean by doesn't work?

What happens when you try to connect? Does the ARDOP console show packets being received? Does the node respond, but fail to establish a connection? Do you get to the node, but not to the RMS application?

73,
John



On 14/07/2024 20:58, Mauro Veiga wrote:
Hi folks. My Winlink Gateway works fine with Packet and VARA HF but not with ARDOP. Is possible to setup BPQ32 to work RMS with ARDOP?

TIA



Re: RMS with ARDOP

 

¿ªÔÆÌåÓý

I assume you are using ARQ mode in ARDOP Chat. I tested with "Send Kbrd Text to OB Queue On" set to CR in the ARDOP Chat Setup and it seems to work fine here. Are you calling the Node Call-SSID or the RMS application Call/SSID?

73,
John


On 15/07/2024 17:23, Mauro Veiga wrote:

The ARDOP port accept conection from The ARDOP CHAT for example. But any commands like Help, Info, BBS or RMS are not passed to BPQ.

Em seg., 15 de jul. de 2024, 12:08, John G8BPQ via <john.wiseman=[email protected]> escreveu:
Can you explain what you mean by doesn't work?

What happens when you try to connect? Does the ARDOP console show packets being received? Does the node respond, but fail to establish a connection? Do you get to the node, but not to the RMS application?

73,
John



On 14/07/2024 20:58, Mauro Veiga wrote:
Hi folks. My Winlink Gateway works fine with Packet and VARA HF but not with ARDOP. Is possible to setup BPQ32 to work RMS with ARDOP?

TIA



Re: RMS with ARDOP

 

The ARDOP port accept conection from The ARDOP CHAT for example. But any commands like Help, Info, BBS or RMS are not passed to BPQ.

Em seg., 15 de jul. de 2024, 12:08, John G8BPQ via <john.wiseman=[email protected]> escreveu:

Can you explain what you mean by doesn't work?

What happens when you try to connect? Does the ARDOP console show packets being received? Does the node respond, but fail to establish a connection? Do you get to the node, but not to the RMS application?

73,
John



On 14/07/2024 20:58, Mauro Veiga wrote:
Hi folks. My Winlink Gateway works fine with Packet and VARA HF but not with ARDOP. Is possible to setup BPQ32 to work RMS with ARDOP?

TIA


Re: RMS with ARDOP

 

¿ªÔÆÌåÓý

Can you explain what you mean by doesn't work?

What happens when you try to connect? Does the ARDOP console show packets being received? Does the node respond, but fail to establish a connection? Do you get to the node, but not to the RMS application?

73,
John



On 14/07/2024 20:58, Mauro Veiga wrote:

Hi folks. My Winlink Gateway works fine with Packet and VARA HF but not with ARDOP. Is possible to setup BPQ32 to work RMS with ARDOP?

TIA


Re: RMS with ARDOP

 

Even testing with only the ARDOP port installed, I cannot connect to the BPQ.? I always test the configurations in local mode before doing it via RF.

Em seg., 15 de jul. de 2024, 10:55, Mark Taylor via <mtaylor=[email protected]> escreveu:

Ok, using that config ARDOP should answer on any call-ssid defined in the application lines.
I assume you have an application called RMS or similar?
I assume you have INTERLOCK=1 also in your VARA port config?
Are you able to attach to the port and control your radio CAT, Xmit, and Rx?


Now, you should probably post your Rigcontrol or Radio configuration parameters. If it is inside your Vara port maybe show that port configuration as well.


(Others are going to be able to provide better assistance. I no longer run Ardop on my node.)



Mark


Re: RMS with ARDOP

 

Ok, using that config ARDOP should answer on any call-ssid defined in the application lines.
I assume you have an application called RMS or similar?
I assume you have INTERLOCK=1 also in your VARA port config?
Are you able to attach to the port and control your radio CAT, Xmit, and Rx?


Now, you should probably post your Rigcontrol or Radio configuration parameters. If it is inside your Vara port maybe show that port configuration as well.


(Others are going to be able to provide better assistance. I no longer run Ardop on my node.)



Mark


Re: RMS with ARDOP

 

My ARDOP port.

PORT
?PORTNUM=7
?ID=ARDOP
?DRIVER=ARDOP
?INTERLOCK=1
?CONFIG
? ADDR 127.0.0.1 9515 ;custom port
? DEBUGLOG TRUE
? CMDTRACE TRUE
? CWID FALSE
? DRIVELEVEL 100
? BUSYWAIT 20
? MAXCONREQ 10
? GRIDSQUARE GG87EA
? FECREPEATS 0
ENDPORT


Em seg., 15 de jul. de 2024 ¨¤s 09:27, Mark Taylor via <mtaylor=[email protected]> escreveu:

Maybe if you posted your ARDOP Port configuration? Did you follow the example in the BPQ documentation?


Re: RMS with ARDOP

 

Maybe if you posted your ARDOP Port configuration? Did you follow the example in the BPQ documentation?


Re: BPQ32.CFG Help required.

 

Oops.. Make the applications...

APPLICATION 1,BBS,,GB7NFD-1,NFDBBS,255
APPLICATION 2,CHAT,,GB7NFD-4,NFDCHT,255


Re: BPQ32.CFG Help required.

 

Ok, did find something else...

You are defining your node alias as NFDBBS. So, connecting to NFDBBS connects you to your node.


Try these and restart...

NODECALL=GB7NFD
NODEALIAS=NFDNOD


APPLICATION 1,BBS,,GB7NFD-1,NFDBBS,0
APPLICATION 2,CHAT,,GB7NFD-4,NFDCHT,0


Re: RMS with ARDOP

 

Hello Mark. I created an ARDOP port, but I can't access the Node/BBS or RMS through it. I did local tests with ARDOP Chat and the modems connect but I can't browse the Node or BBS, the BPQ doesn't respond to commands. On the VARA port, access to the Node, BBS and RMS works very well with VARA Term or Winlink Express. I wonder if I wouldn't need some special configuration on the ARDOP port.

Em seg., 15 de jul. de 2024 ¨¤s 08:02, Mark Taylor via <mtaylor=[email protected]> escreveu:

Yes, simply create an ardop port. If it shares a radio with the Vara HF port you will need to Interlock them with the same number. Make sure the port responds to any incoming winlink connections and it is directed to the RMS application, just like the Vara port does. Include a WL2KREPORT line once it is working.

The most difficult part is calibrating the ports so that both result in an acceptible ALC at the radio while transmitting.


Mark


Re: BPQ32.CFG Help required.

 

Not a reason for affecting your connections, but, there is normally no reason to be listening on two different UDP ports. What is your reason for that?

Also, there is BTINTERVAL defined twice. Doesn't hurt anything but only defining it once, with a 15 minuted interval makes it clearer.
And, IDINTERVAL needs a value.