¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Adding SSID to APPLICATION TALK?
No, you can use any ssid not used for other purposes. 73, John
By John G8BPQ · #42257 ·
Re: BPQ32 Connect Script Problems
I just recently ran into a situation where I needed to do the same thing, i.e. change frequencies via ELSE. I tend to use 30 second pauses whenever something fails and has to move on with an ELSE, so
By Lee Bengston · #42256 ·
Re: Changing the VARA mode
[email protected]> wrote: Thank-you Sir! Also I see one can override the port default with the VN, VW, etc. parameters in the scan lines. That's great as I have some frequencies where I don't want
By Lee Bengston · #42255 ·
Adding SSID to APPLICATION TALK?
Hello everyone. Are there any issues with adding a SSID to the TALK Node Application? Such as KA3VSP-2? [image: Screenshot 2024-10-01 195740.png] Best, Brian, KA3VSP
By Brian Pasternak · #42254 ·
Re: VARA port default setting
Thank-you for the details John. Lee K5DAT >
By Lee Bengston · #42253 ·
Re: VARA port default setting
If you port is set for 500 it won't allow incoming 2300 connects but if set to 2300 it will accept 500 so long as you have the enable 500 check box set. 73, John
By John G8BPQ · #42252 ·
Re: Modernizing the HTML control panel
Hi Rik. I have nothing in principal against you updating the web pages. They are the minimum to do the job of managing the node. The files are not actually used any more, the pages are included in the
By John G8BPQ · #42251 ·
Re: Modernizing the HTML control panel
Using secure HTTP (shttp://) would be a good idea, too. 73 - Rick KE0GB
By Richard Hendricks - KE0GB <rickh6155@...> · #42250 ·
Modernizing the HTML control panel
This is primarily for John G8BPQ, but I would be interested in other opinions too. I am a web developer with 20 years experience and I would like to offer to update the BPQ HTML pages to modern
By Rik M7GMT · #42249 ·
Re: Changing the VARA mode
Yes, you can add BW commands to the connect script, after attach and before connect. Format is BW500, BW2300 or BW2750 and for VARAFM FM1200 or FM9600. If you include a BW command in the port config
By John G8BPQ · #42248 ·
VARA port default setting
Does the default (bandwidth) setting for a VARA port impact outbound only, or does it impact incoming connections also? Thanks, Lee K5DAT
By Lee Bengston · #42247 ·
Re: Changing the VARA mode
[email protected]> wrote: Thanks Mark! Yes, up until now I've been running VARA 500 exclusively, so that has been checked all along. > > 73, Lee K5DAT
By Lee Bengston · #42246 ·
Re: Changing the VARA mode
Yes, in the connect script, after the attach you can use the BWxxxx to change your transmit bandwidth. Be sure and check to allow 500hz connections in the Vara TNC settings.? It has always worked for
By Mark Taylor · #42245 ·
Changing the VARA mode
Hello, To provide an example, I'm scanning both 20m and 40m during the day, and the same BPQ port for VARA applies. The default mode is BW500, and that's needed for the 40m frequency. On 20m I could
By Lee Bengston · #42244 ·
Re: Hierarchical routing not working
Eric, I'm guessing you are either completely frustrated with this or you have it fixed.? I'd be curious to know if you fixed it... If not I think there are two possibilities. 1. Something has been
By Mark Taylor · #42243 ·
Re: Missing calls in MH ?
Another example from today: In the monitor window: *20:18:01R KK4DIV-1>K0WAV-7 Port=2 <D C P>* but in MH list no KK4DIV-1 *mh 2* *RFTMG:K7TMG-7} Heard List for Port 2* *K7TMG. ? ? 00:00:08:09*
By Sholto (K7TMG) · #42242 ·
Re: Node Taking Application Callsigns
HIDENODES only stop the display of nodes with an alias starting with # in the NODES display. NODE=0 disables the node functions and only allows connects to your applications. The NODECALL is ignored
By John G8BPQ · #42241 ·
Re: Node Taking Application Callsigns
Never mind - I figured it out.? SIMPLE already included the NODE and HIDENODES settings and my configuration reversed them.? I guess HIDENODES hides the subject node as well :) Thanks for the
By Murray Johnson VE3KNO · #42240 ·
Re: Node Taking Application Callsigns
Try setting NODE=1
By Mark Taylor · #42239 ·
Re: Node Taking Application Callsigns
Thanks Mark.? The NODECALL and NODEALIAS are right at the top of the config file: SIMPLE LOCATOR=43.397939, -79.976857 NODECALL=VA3AMJ-7 NODEALIAS=CARLYL CTEXT: ...and so on.? Further down I have:
By Murray Johnson VE3KNO · #42238 ·