Re: BPQ VARA Beacon
This is my config to send APRS beacons via VARA HF, the PTT in VARA is done via CAT from BPQ:
;--------------------------------------- ?HF 14.103 / 10.1482 PACKET PORT
By
Heber Soto, NP4JN
·
#43049
·
|
Re: Incoming Winlink Messages
If the incoming connect is to the bbs call instead of the rms call the messages will go to the bbs. So long as the forwarding script for RMS tries the Internet first then a packet station it should
By
John G8BPQ
·
#43048
·
|
Re: Feature Request - Send new messages
Ok, Lee.
I think it would be a good idea to delay a bit and to randomize the time so it is less likely to connect to several simultaneously. I'll look into it.
73,
John
By
John G8BPQ
·
#43047
·
|
Re: BPQ32 APRS not Digipeating all packets.
Digipeater is NP4JN-11
FTM-400 is NP4JN-9
FT3D is NP4JN-7
By
Heber Soto, NP4JN
·
#43046
·
|
Re: BPQ VARA Beacon
Hello Jean,
I don't know about VARA FM because I've never used it, but the only way I
can think of on VARA HF is to set up a KISS over TCP port in BPQ that
points to the VARA KISS port. Then others
By
Lee Bengston
·
#43045
·
|
BPQ VARA Beacon
Hi, There is a way to send a Beacon in VARA? and VARA HF using BPQ?
--
73 de Jean,
VA2OM / VE2PKT
By
Jean L¨¦tourneau
·
#43044
·
|
Re: BPQ32 APRS not Digipeating all packets.
This causes me to question the calls used in each aprs device.? They obviously cannot be duplicated in any device, including BPQ.
Nodecall and the application line calls might also affect this. Do
By
Mark Taylor
·
#43043
·
|
Re: BPQ32 APRS not Digipeating all packets.
Mark thanks for the input.
On this:
I hesitate to even get into this but if this were mine I would try the following...
Port 2 & 4 comment out these
By
Heber Soto, NP4JN
·
#43042
·
|
Incoming Winlink Messages
John, G8BPQ
We have been developing a VARA HF forwarding network here in the states, we
are allowing portable hf station access to packet node & bbs, Winlink RMS &
APRS sms & email services. More
By
N3MEL - Glenn
·
#43041
·
|
Re: Feature Request - Send new messages
Lee,
I have made a few changes here to deal with the VARA HF problem you describing. I have adjusted my forwarding script and
added a PAUSE line between the first attempt and the 2nd, then the script
By
N3MEL - Glenn
·
#43040
·
|
Re: NTS Messages
Some good information here. Thanks to all.
By
Bob Plank KK4DIV
·
#43039
·
|
Re: BPQ VARA Modem Port Issue
Mark,
You did it! Thank you. That did the trick. In short, there are no duplicate calls in the BPQ configuration. Some of this syntax looked like magic. My actual BPQ node (not the test station) is
By
Gaston Gonzalez
·
#43038
·
|
Re: BPQ32 APRS not Digipeating all packets.
I hesitate to even get into this but if this were mine I would try the following...
Port 2 & 4 comment out these lines:
UNPROTO=APBPQ1,WIDE1-1,WIDE2-1
BCALL=NP4JN-11
The path and bcall used is
By
Mark Taylor
·
#43037
·
|
Minimize BPQ to Tray Loses menu
I'm a new user of BPQ32 and apps on Win10. I've probably done something wrong but I find that sometimes when I minimize BPQ32 and apps to the system tray that I will lose the menu you get when you
By
Mike
·
#43036
·
|
Re: BPQ VARA Modem Port Issue
I'm now wondering if having the same value for NODEALIAS and BBS ALIAS is confusing things. But, that is in your original config. If it is still like that you should have different values for
By
Mark Taylor
·
#43035
·
|
Re: BPQ VARA Modem Port Issue
Kayne,
Thanks for the pointers. I confirmed that I can establish a successful outbound VARA HF connection via the ATT and C commands. It seems that the problem is just with inbound connections into
By
Gaston Gonzalez
·
#43034
·
|
BPQ32 APRS not Digipeating all packets.
Hello
I run BPQ32 APRS in various ports, port 2 is APRS and BBS 145.090 in the same channel, port 4 is APRS 144.390, port HF VARA HF etc.
I have noticed that in VHF port 2 & 4 not all packets are
By
Heber Soto, NP4JN
·
#43033
·
|
Re: BPQ VARA Modem Port Issue
Lee,
Thank you for providing this level of detail. I am successfully able to connect out to a Winlink RMS gateway from BPQ. So, at least I know that the modem works.
***
By
Gaston Gonzalez
·
#43032
·
|
Re: BPQ VARA Modem Port Issue
One can also use an AGW client like easyterm with bpq's AGW emulator/server. From there you can connect to node 'SWITCH' and issue the C or ATT commands as needed.
Latency I am not sure, but VARA
By
N9SEO
·
#43031
·
|
Re: BPQ VARA Modem Port Issue
Hello Gaston,
* I am able to connect using VARA HF to multiple Winlink RMS stations
using Pat from both the BBS station as well as from my other client
station that I have been using to access
By
Lee Bengston
·
#43030
·
|