Date
Re: Changing the VARA mode
Yes, you can add BW commands to the connect script, after attach and before connect. Format is BW500, BW2300 or BW2750 and for VARAFM FM1200 or FM9600. If you include a BW command in the port config
By John G8BPQ · #42248 ·
VARA port default setting
Does the default (bandwidth) setting for a VARA port impact outbound only, or does it impact incoming connections also? Thanks, Lee K5DAT
By Lee Bengston · #42247 ·
Re: Changing the VARA mode
[email protected]> wrote: Thanks Mark! Yes, up until now I've been running VARA 500 exclusively, so that has been checked all along. > > 73, Lee K5DAT
By Lee Bengston · #42246 ·
Re: Changing the VARA mode
Yes, in the connect script, after the attach you can use the BWxxxx to change your transmit bandwidth. Be sure and check to allow 500hz connections in the Vara TNC settings.? It has always worked for
By Mark Taylor · #42245 ·
Changing the VARA mode
Hello, To provide an example, I'm scanning both 20m and 40m during the day, and the same BPQ port for VARA applies. The default mode is BW500, and that's needed for the 40m frequency. On 20m I could
By Lee Bengston · #42244 ·
Re: Hierarchical routing not working
Eric, I'm guessing you are either completely frustrated with this or you have it fixed.? I'd be curious to know if you fixed it... If not I think there are two possibilities. 1. Something has been
By Mark Taylor · #42243 ·
Re: Missing calls in MH ?
Another example from today: In the monitor window: *20:18:01R KK4DIV-1>K0WAV-7 Port=2 <D C P>* but in MH list no KK4DIV-1 *mh 2* *RFTMG:K7TMG-7} Heard List for Port 2* *K7TMG. ? ? 00:00:08:09*
By Sholto (K7TMG) · #42242 ·
Re: Node Taking Application Callsigns
HIDENODES only stop the display of nodes with an alias starting with # in the NODES display. NODE=0 disables the node functions and only allows connects to your applications. The NODECALL is ignored
By John G8BPQ · #42241 ·
Re: Node Taking Application Callsigns
Never mind - I figured it out.? SIMPLE already included the NODE and HIDENODES settings and my configuration reversed them.? I guess HIDENODES hides the subject node as well :) Thanks for the
By Murray Johnson VE3KNO · #42240 ·
Re: Node Taking Application Callsigns
Try setting NODE=1
By Mark Taylor · #42239 ·
Re: Node Taking Application Callsigns
Thanks Mark.? The NODECALL and NODEALIAS are right at the top of the config file: SIMPLE LOCATOR=43.397939, -79.976857 NODECALL=VA3AMJ-7 NODEALIAS=CARLYL CTEXT: ...and so on.? Further down I have:
By Murray Johnson VE3KNO · #42238 ·
Re: Node Taking Application Callsigns
Be sure your NODECALL and NOALIAS is not contained within a multiline comment.
By Mark Taylor · #42237 ·
Node Taking Application Callsigns
I'm working through the configuration of a LinBPQ node.? Using the terminal on the html page, I see that the node is taking the SSID and ALIAS of either the chat server or the BBS (depending upon
By Murray Johnson VE3KNO · #42236 ·
Re: Missing calls in MH ?
I'm sure I was looking at your -8 then...
By Mark Taylor · #42235 ·
Re: Missing calls in MH ?
Mark, Port 2 is the SCS Tracker running the bpq hostmode driver. *RFTMG:K7TMG-7} Ports* *1 Loopback* *2 SCS Tracker (hostmode)* *3 Telnet* There is no tcp/udp port on this instance of BPQ. This is on
By Sholto (K7TMG) · #42234 ·
Re: Hierarchical routing not working
Another possibility Eric is that you give someone admin access over the web to your node to double check your settings.? At this point it wouldn't hurt. I'll be glad to if you want.. email on my node
By Mark Taylor · #42233 ·
Re: Hierarchical routing not working
Yes, they are being treated as directed. I guess it would be useful to display your HA as part of the routing trace, but it seems it doesn't think you are in USA or NOAM! 73, John
By John G8BPQ · #42232 ·
Re: Hierarchical routing not working
Here are the logs from the recent @USA and @NA messages: 240929 07:50:51 |KA1VSC-4 Incoming Connect from KA1VSC 240929 07:50:51 >KA1VSC-4 [BPQ-6.0.24.42-B1FWIHJM$] 240929 07:50:51 >KA1VSC-4 240929
By Eric H. Christensen · #42231 ·
Re: Missing calls in MH ?
Port 2 is your AXIP port. On windows my AXIP Port MHeard List only shows direct connections to my node.? Not pass through connections.? Could it be the same on linux?
By Mark Taylor · #42230 ·
Re: Hierarchical routing not working
I don't think so. ?WG3K.#SMD.MD.USA.NOAM is the H Address. ?#SMD.MD.USA.NOAM is the H Route. The only things I can imagine at this point is, are those copy/paste or typed in.? I sometimes will
By Mark Taylor · #42229 ·