Acually, it looks like you are trying to access your node as if you are a gateway, and since you are not it will indeed fail.
?
It's easier to do what you want without being a gateway, I believe.? (If I am wrong then John will correct me.)
?
Comment out the following lines:
CMS=1 ;Enable CMS Gateway
RELAYAPPL=RMS
APPLICATION 4,RMS,C 1 CMS,K1KSR-10,MHRMS,255
and remove everything below this line.
?
?
Now, you are not a gateway, but BPQ will periodically check your Winlink messages for you if you make a small change in your BBS User record.
?
In your own BBS User record, check Poll RMS.? In the boxes where it says For SSID's, enter a zero in the first box. (and even that may not be needed.)
Finally, enter your Winlink password in the CMS Pass text box.
Save the user record.
Restart BPQ since you changed the config file.
?
BPQ will check your messages periodically and place your received messages in the BBS as a personal message to you.? You can access the BBS remotely over RF by connecting to your BBS, or locally using Webmail.
?
?
If I am wrong about BPQ checking your messages without being a gateway then you will need to request that.? It takes about 3 days.? We can reconfigure later if necessary, and fix the other errors in your config file.
?
?
--
73,
Mark, N5MDT
Montgomery, Texas
?
?
?