Re: TNC issue


 

You said "Windows 7" but the config is for Linux. Swap the /dev/ttyACM0 for COM4 or whatever your port is.


On Fri, Nov 8, 2024, 14:55 Keith G1GXB via <g1gxb=[email protected]> wrote:
Hi
I only ever run a PK232 with Windows but did find it preferred 9600 bauds? as it use to miss commands at 19200 bauds and loss itself.
I suggest you double check it is in Kiss, watch for the double flash on power up and try slower speed.
?
73 de Keith G1GXB?
?
From: Thomas Testa via groups.io
Sent: Friday, November 8, 2024 6:47 PM
Subject: Re: [bpq32] TNC issue
?
Thank you for your reply Mark . I do believe the port is configured correctly. It just seems to me the program isn¡¯t looking for the TNC. Usually a program with report a port error but absolutely nothing is happening.
?





On Friday, November 8, 2024, 1:20 PM, Mark Taylor <mtaylor@...> wrote:

A look at your port configuration would help.
?

Virus-free.