This is rather odd. CLEANTXBUFFER should only be sent when a session
times out and this is happening within a second of the connect
attempt. I suppose it is possible that the CLEANTXBUFFER is from a
previous session, but it is still odd. I'll see if I can work out
what could be happening.
When this happens what does the TNC state show in the VARA driver
window?
73,
John
On 19/10/2024 15:25, Lee Bengston
wrote:
toggle quoted message
Show quoted text
Greetings.
I've been finding the radio stuck on the same frequency
lately. It's always the VARA port that is considered to be
still in use.? It happened again this morning, and below is
what's in the BBS log.? The radio is a Yaesu FTdx10.
241019 13:34:19 |N3MEL ? ? Connecting to BBS N3MEL
241019 13:34:19 <N3MEL ? ? *** CONNECTED
241019 13:34:19 ?N3MEL ? ? Script MSGTYPES PTBR
241019 13:34:19 >N3MEL ? ? ATT 7
241019 13:34:19 <N3MEL ? ? SHAWNO:K5DAT-7} Ok
241019 13:34:19 >N3MEL ? ? BW500
241019 13:34:20 <N3MEL ? ? VARA} OK
241019 13:34:20 >N3MEL ? ? RADIO 14.1065 USB
241019 13:34:20 <N3MEL ? ? Mode and Frequency Set OK
241019 13:34:20 >N3MEL ? ? C N3MEL-2
241019 13:34:21 <N3MEL ? ?
VARA} CLEANTXBUFFER BUFFEREMPTY
241019 13:35:06
<N3MEL ? ? VARA} Failure with K5DAT-1 N3MEL--
241019 13:35:06 |N3MEL ? ? N3MEL Disconnected
Subsequent attempts to forward via VARA fail because the
port is not released.
241019 13:36:56 |N9LYA ? ? Connecting to BBS N9LYA
241019 13:36:56 <N9LYA ? ? *** CONNECTED
241019 13:36:56 ?N9LYA ? ? Script MSGTYPES PTBR
241019 13:36:56 >N9LYA ? ? ATT 7
241019 13:36:56 <N9LYA ? ? SHAWNO:K5DAT-7} Error - Port in
use
241019 13:47:00 |K7EK ? ? ?Connecting to BBS K7EK
241019 13:47:00 <K7EK ? ? ?*** CONNECTED
241019 13:47:00 ?K7EK ? ? ?Script MSGTYPES PTBR
241019 13:47:00 >K7EK ? ? ?ATT 7
241019 13:47:00 <K7EK ? ? ?SHAWNO:K5DAT-7} Error - Port in
use
241019 13:47:00 |K7EK ? ? ?K7EK Disconnected
Searching through the log for "
CLEANTXBUFFER BUFFEREMPTY",
found an older instance where the same thing happened.
241019 02:04:54 |W7EES ? ? Connecting to BBS W7EES
241019 02:04:54 <W7EES ? ? *** CONNECTED
241019 02:04:54 >W7EES ? ? ATT 7
241019 02:04:54 <W7EES ? ? SHAWNO:K5DAT-7} Ok
241019 02:04:54 >W7EES ? ? BW2300
241019 02:04:55 <W7EES ? ? VARA} OK
241019 02:04:55 >W7EES ? ? RADIO 7.100 USB
241019 02:04:55 <W7EES ? ? Mode and Frequency Set OK
241019 02:04:55 >W7EES ? ? C W7EES
241019 02:04:56 <W7EES ? ? VARA} CLEANTXBUFFER BUFFEREMPTY
241019 02:05:06 <W7EES ? ? Sorry, Can't Connect - Channel
is busy
241019 02:05:06 |W7EES ? ? W7EES Disconnected
Sure enough, the next attempt to use VARA port 7 (14
minutes later) failed:
241019 02:19:19 |K1AJD ? ? Connecting to BBS K1AJD
241019 02:19:20 <K1AJD ? ? *** CONNECTED
241019 02:19:20 ?K1AJD ? ? Script MSGTYPES PTBR
241019 02:19:20 >K1AJD ? ? ATT 7
241019 02:19:20 <K1AJD ? ? SHAWNO:K5DAT-7} Error - Port in
use
241019 02:19:20 |K1AJD ? ? K1AJD Disconnected
This looks like it's at least partially a VARA issue, but
it seems BPQ should still de-attach the port.
73,
Lee K5DAT