Further to this.
1. I have confirmed with a user of the DX200 that it received Mono/Poly, PB & porta from ACED parameter change (3b.), but did not receive PLG150DX's XG controller-assign parameter changes (4b.) We tried the following but it didn't work:
F0 43 10 4C 07 02 00 0F F7 - assign PLG150DX part no. 16
F0 43 10 4C 08 0F 04 0n F7 - set part 16's receive channel to n+1
F0 43 10 4C 08 0F 20 00 F7 - turn part 16 mod-wheel pitch-mod off
F0 43 10 4C 08 0F 1E 60 F7 - turn part 16 mod-wheel filter up
So it seems DX200 users are stuck with mod-wheel pitch-mod & inoperative aftertouch.
2. The FS1R receives operator AM sensitivity and pitch-EG parameters from DX7 single-voice ACED bulk dump (3a.) sent before DX7 single-voice VCED bulk dump, but mono/poly, PB and porta are in FS1R performance part parameters and controller assign in FS1R performance common parameters.
3. The DX5 and DX1 receive TX7 performance data (2a., 2b., 2c.)
toggle quoted message
Show quoted text
--- In YamahaDX@..., "Greg" <gholwell60@...> wrote:
1. This also affects Mono/Poly, pitch-bend range and portamento mode/time.
2. The DX200 manual says that the ACED controller-assign parameters (3a.) are not used but does not include the XG multi-part sysex (4.) used by the PLG150DX. Someone out there with a DX200 (which, according to another post, includes the PLG150DX board) may be able to confirm which of these work.
--- In YamahaDX@..., "Greg" <gholwell60@> wrote:
Among Yamaha's 6-operator FM synths I have found 4 different ways of assigning
controllers to various functions (e.g. pitch modulation depth for the mod wheel).
1. DX7 Mark I Function parameter changes (F0 43 1n 08)
2a. TX7/TX816 Performance bulk dump (F0 43 0n 01)
2b. TX7/TX816 Performance parameter changes (F0 43 1n 04)
2c. TX7/TX816 64-Performance bulk dump (F0 43 0n 02)
(These synths also receive 1.)
3a. DX7II/DX7S/TX802 ACED (single-voice supplement) bulk dump (F0 43 0n 05)
3b. DX7II/DX7S/TX802 ACED parameter changes (F0 43 1n 18)
3c. DX7II/DX7S/TX802 AMEM (32-voice supplement) bulk dump (F0 43 0n 06)
4a. PLG150DX XG multi-part bulk dump (F0 43 0n 4C LL LL 08 0p nn)
4b. PLG150DX XG parameter changes (F0 43 1n 4C 08 0p nn)
(These synths do not use the controller-assign parameters in 3a.)
The Java program in dx7param.zip in the Files section generates 1. before 2a./3a. so
the same bulk dump can be used for both DX7 Mark I (with channel changed by the Java
program in dx7chan.zip) and either DX7II or TX7.
For 4a./4b. use an XG editor such as:
XGC (free from www.midiox.com, base XG + DB50XG/SW60XG/MU10 2-element voice loader)
XG-Gold (base XG + QS300/DB50XG/SW60XG/MU10 4-element voice editor)
XG-Wizard (SW1000XG)
XGedit, XG-Pad (generic)
Note that filter modulation is inoperative here.