Can't get FT 60R to scan all 5 bands


 

As per instructions I started in VFO>Band>P>All> waited for the P to stop flashing, pushed up arrow & then tried down arrow, same thing, it will not scan all 5 bands. Only one at a time. Do I need to do any thing after the flashing P is set to ALL?


 

开云体育

Have you tried push and hold the arrow buttons?

Jardy Dawson WA7JRD

Message sent by....Oh look!! Pretty lights!!


On Dec 9, 2022, at 20:37, dcx3420 via groups.io <dcx3420@...> wrote:

?
As per instructions I started in VFO>Band>P>All> waited for the P to stop flashing, pushed up arrow & then tried down arrow, same thing, it will not scan all 5 bands. Only one at a time. Do I need to do any thing after the flashing P is set to ALL?


 

Thanks, Jardy. Just gives me the selections as turning the dial to ALL. Tried hold the BAND button down too.

Gary KY8M


On Saturday, December 10, 2022, 12:19 AM, JARDY DAWSON via groups.io <JARDY72@...> wrote:

Have you tried push and hold the arrow buttons?

Jardy Dawson WA7JRD

Message sent by....Oh look!! Pretty lights!!


On Dec 9, 2022, at 20:37, dcx3420 via groups.io <dcx3420@...> wrote:

?
As per instructions I started in VFO>Band>P>All> waited for the P to stop flashing, pushed up arrow & then tried down arrow, same thing, it will not scan all 5 bands. Only one at a time. Do I need to do any thing after the flashing P is set to ALL?


 

Finally got it, went back to the manual. I had to:4. Press and hold in the [V/M(PRI)] key for one second to start scanning.