Re: FT-101Z Tuning Issue


 

开云体育

I agree with the below

Until you can solve the meter issue you could try:

At plate dip, power out should be max – measured on external power/swr meter - provided the final tubes are aligned ok

Then you can maximise PO with preselect and load on the same external meter

?

From: [email protected] [mailto:[email protected]] On Behalf Of Alistair GM4ENF via groups.io
Sent: Sunday, 4 December 2022 5:56 AM
To: [email protected]
Subject: Re: [Yaesu-FT-101] FT-101Z Tuning Issue

?

Your description of the procedure you carried out is not too clear.? when you worked through the tuning/loading process did? the equipment respond as it should?? ie load giving an Increase in Ic followed by dip when adjusting tuning.? If so have you checked using another meter/device to see if there is any output irrespective of what the PO meter is showing???