开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育

DR4088LN-CS Excellent


 
Edited

I am building a small automated layout with detection using Stand-Alone Loconet and NCE PowerCab Command STATION.

The original plan had been to use a Digitrax BDL168.

Having bought both a Digitrax PR4 and a BDL168 and spent several days building a loconet terminator it soon became apparent that this configuration was too complicated with regard to RailSync together with the lack of Command Station ground connection hich needed a pseudo ground circuit!

I finally decided that a better way to go was to change to the Digikeijs DR4088LN-CS and a RR Circuits Locobuffer USB,? with a Sprog3 for a Command Station.

As neither of these two devices will act as a loconet terminator I also purchased a M?llehem G?rdsproduktion Loconet Terminator.

Having wired it all together on a small test board the DR4088LN-CS worked first time without any problems and at less than half the cost of a BDL168 for the same number of Inputs (16).

?

Colin