Re: Z21 App. Selecting correct module type for feedback.


 

I have answered my own question.

?

What works for me is to use the feedback module type Roco 10808 CAN which has two settings.

?

RA - Report Address (1-20) is the first address of each block of 8 Inputs.

I - Input (1-8). Is the actual Input number of block of 8 Inputs.

?

This then gives the following.

?

With the first DR4088LN-CS set with a start address of 1 then the first 8 Inputs are

?

Left Hand Input block terminals numbered1-8

Sensor 01 Input Terminal 1 = Roco setting RA=1 I=1

Sensor 02 Input Terminal 2 = Roco setting RA=1 I=2

Sensor 03 Input Terminal 3 = Roco setting RA=1 I=3

Sensor 04 Input Terminal 4 = Roco setting RA=1 I=4

Sensor 05 Input Terminal 5 = Roco setting RA=1 I=5

Sensor 06 Input Terminal 6 = Roco setting RA=1 I=6

Sensor 07 Input Terminal 7 = Roco setting RA=1 I=7

Sensor 08 Input Terminal 8 = Roco setting RA=1 I=8

?

Right Hand Input block terminals numbered 9-16

Sensor 09 Input Terminal 09 = Roco setting RA=2 I=1

Sensor 10 Input Terminal 10 = Roco setting RA=2 I=2

Sensor 11 Input Terminal 11 = Roco setting RA=2 I=3

Sensor 12 Input Terminal 12 = Roco setting RA=2 I=4

Sensor 13 Input Terminal 13 = Roco setting RA=2 I=5

Sensor 14 Input Terminal 14 = Roco setting RA=2 I=6

Sensor 15 Input Terminal 15 = Roco setting RA=2 I=7

Sensor 16 Input Terminal 16 = Roco setting RA=2 I=8

?

With the second DR4088 S88N-SC which has start Address of 17 because it is slaved from the first DR4088 then the first 8 Inputs.

?

Left Hand Input block terminals numbered1-8

Sensor 17 Input Terminal 1 = Roco setting RA=3 I=1

Sensor 18 Input Terminal 2 = Roco setting RA=3 I=2

Sensor 19 Input Terminal 3 = Roco setting RA=3 I=3

Sensor 20 Input Terminal 4 = Roco setting RA=3 I=4

Sensor 21 Input Terminal 5 = Roco setting RA=3 I=5

Sensor 22 Input Terminal 6 = Roco setting RA=3 I=6

Sensor 23 Input Terminal 7 = Roco setting RA=3 I=7

Sensor 24 Input Terminal 8 = Roco setting RA=3 I=8

?

Right Hand Input block terminals numbered 9-16

Sensor 25 Input Terminal 09 = Roco setting RA=4 I=1

Sensor 26 Input Terminal 10 = Roco setting RA=4 I=2

Sensor 27 Input Terminal 11 = Roco setting RA=4 I=3

Sensor 28 Input Terminal 12 = Roco setting RA=4 I=4

Sensor 29 Input Terminal 13 = Roco setting RA=4 I=5

Sensor 30 Input Terminal 14 = Roco setting RA=4 I=6

Sensor 31 Input Terminal 15 = Roco setting RA=4 I=7

Sensor 32 Input Terminal 16 = Roco setting RA=4 I=8

?

If you then take this on to the next Feedback module whose first Input is sensor 33 then:

?

Left Hand Input block terminals numbered1-8

Sensor 33 Input Terminal 1 = Roco setting RA=5 I=1

?

Right Hand Input block terminals numbered 9-16

Sensor 40 Input Terminal 09 = Roco setting RA=5 I=1

?

The next Feedback module whose first Input is sensor 49 then:

?

Left Hand Input block terminals numbered1-8

Sensor 49 Input Terminal 1 = Roco setting RA=7 I=1

?

Right Hand Input block terminals numbered 9-16

Sensor 56 Input Terminal 09 = Roco setting RA=8 I=1

?

Etc.

?

This does mean however that the top limit of sensors that the Z21 App in this configuration will display is 160 but only if you start numbering your DR4088 with address 1

?

The first Roco setting is

First Sensor (1) Input Terminal 1 = Roco setting RA=1 I=1

?

Should you start with your DR4088 at address 33 then the first Roco setting is

First Sensor (1) Input Terminal 1 = Roco setting RA=5 I=1

So the total number of sensors that the Z21 App will display will be 136

?

Now I am not saying that this is the only or correct solution but it will work for me.

?

Also note that this only applies to the new version of the Z21 App as the original version of the App does not have the Roco 10808 CAN type listed.

Join [email protected] to automatically receive all group messages.