the cobalts are powered?by dr5000 the cobalt frogs are wired frog to the common and the track feed for the frogs are left and right on the cobalts I am not using the frog connection on the cobalts
On Tue, Jan 7, 2025 at 11:33?AM Iain Morrison via <w.iain.morrison=[email protected]> wrote:
By resistor packs do you mean DCC Filters (snubbers)??
Are you using the frog output on the Cobalts? If you are then you will be powering the frogs from the accessories bus I.e. the YD9401. When using separate boosters for the track then you need to use the separate SPDT switch that is on the Cobalts and take the feeds from the track power feeding the turnouts.
Many Thanks
Iain Morrison
On Tue, 7 Jan 2025 at 11:18, Alan Watt via <overdenestation=[email protected]> wrote:
ok bought some of them resistor packs?
I have two boosters for the track power only and the point motors all run from the dr5000/9401
put the resistor pack on the dr5000 and when I change? a point(cobalt) most of my tracks shows occupancy while the point moves