Re: False Positives YD6016


 

On Wed, Oct 2, 2024 at 10:44 AM, Dave wrote:
We have had 6 or 7 false positives today but all could be cleared by activating the false feedbacks using ?track tester or a finger across the rails.?
Okay.... that's not false positive, that's stuck positive....? So it looks like you're on the wrong foot.

we have added 470ohm resistors to all feedback on one of our DR4088LN CS Boxes.
After several hours of running a single train around the layout one feedback failed to de-activate when leaving the block.?

This feedback remained active even when we removed the feed from the DR4088LN.?
?
As I already wrote, resistors on a YD6016xx-CS don't help. But acrually you are notalking about the Digikeijs modules, not the YaMoRC ones ??

Those "stuck" feedback originate almostt 100% sure from comminications problem. Either between Modules and the Command Station and/or from Command Station to iTrain.

Question: Which connection/protocol do you use to connect iTrain to your command station?

Greets,
Karst

P.S. the DR4088LN are notorious for messing up LocoNet communication.... The YD6016LN though should not give problems.... unless a DR4088LN has "f#%$^-ed" up the LocoNet....?
?