On Fri, Mar 22, 2024 at 08:29 AM, sotars wrote:
That comment from Karst was the first time I had heard of the limitations on the number of DR4088LN units
That is incorrect quoting ! ? I was referrring to you, mentioning that you had all DR5088RC !!! when I wrote that I never had seen the problem before.
?
|
Wed, Mar 20, 12:47?AM (3 days ago)
?
|
? |
|
? |
?
?
?
?
?
5088RC and I use railcom if that matters.
?
Thanks Eddie
?
?
What type of feedbask units do you have ?
?
It was the first time I heared about DR5088RC problems in this context.
The DR4088LN problem is already known for more than 5 years.... That also the DR5033 suffer from the same dissease (hanging up LocoNet on high trafic) became aparent quite soon after that 4088LN problem was discovered.
?
But looking at your schematic... There is some things I would do differently.?
?
First: give each DR5088RC a different "Report Delay"( start with 750 or 1000 and then increment by 130 on each subsequent DR5088 )
Second: consider your DR5033 to operate from them as CDE device behind the DR5039
Third: get rid of the 5099. One direct LocoNet cable from YD7001 LocoNet-B to DR5039 will do.
?
Since you now effectively only have left 3x DR4099LN, thy should report just fine.
?
Further, you may want to switch on this:

?
Greets,