Re: De sensitise DR4088LN-CS inputs.


 

You are not ¡®tying¡¯ the 1-8 outputs (or 9-16) together, they remain completely separate as they are today. You are placing a shunt resistors between the feedback e.g. feedback 1 and the C terminal for that bank.?

This means that most of the current shunts through the resistor rather than going through the DR4088xx.?

Many Thanks

Iain Morrison



On Sun, 17 Sep 2023 at 20:00, Don Charabin <scentgrasslake@...> wrote:

[Edited Message Follows]

Ryan: I have read about adding resistors to the DR4088 to desensitize the device but never understood how this was to be accomplished until I saw your photos. Awesome, thanks!!!


Just to help me understand further, though, it was my impression that each of the 1-8, 9-16 detection connections were to be separate from each other; ?the way you have them soldered together to the common ¡®C¡¯ is they are all tied together, will then a detection on any one them show detection on all of them, thus making it a tad confusing as to which block is occupied?