Well I looked up the specs for the tantalum box and it is 257 amps at 1.4 volts requiring 360 watts.? I have 12 vac at 500 amps available so I presume I have enough power.? I also looked up the current carrying capacity of the 3/8" dia steel threaded rods that make up the pass thru's.? It was very much less than it needed to be.? So I will be changing out the two 3/8" steel rods for two 1/2" copper rods and between the two parallel pass thru's I should have a true 500 amps rated capability.? I am also stepping up to 4 each power feeds leading to the tantalum box and 4 each leads going to chamber ground.? Each lead should be 90 amps so that is 360 amps of capability leading to and exiting away from the box. ? The main feeds to the pass thru's are 3/4" copper stranded cable so that is 500 amp plus. ? Along with cleaning up all contacts and eliminating all stainless steel conductors in the system I think the next time I power the system up it will glow white hot only where it is supposed to and not along the path. ? This electricity stuff is nearly as tricky as vacuum. ? ? ?? On Thu, Oct 30, 2014 at 5:19 PM, Lindsay Wilson lindsay@... [VacuumX] <VacuumX@...> wrote:
|