System info: Pi5, x64, x11 (Wayland disabled).?
varaHF and varaFM installed and previously working in wine.
Rig control via FLrig.?
Radio: 991a
VaraHF ver 4.8.9
VaraFM ver 4.3.8
?
Current condition:
VaraHF will transmit and receive audio in tuning mode,? both applications will ptt the radio (settings>soundcard>Tune).
?
?
Problem:
VaraHF hangs on connect, log indicates "Wrong command:? CONNECT KM4PVB KN4CCQ"
VaraFM hangs on connect, log indicates "Wrong command: CONNECT KM4PVB WC4EOC-8"
Can confirm audio in and out, and radio control working fine in both applications within wine.
?
Additional information:
In VaraFM, while attempting to use "AutoTune", entering WC4EOC-8 returns "bad callsign" when attempting to autotune.
?
removing the ssid will cause the radio to transmit the test packets, but the remote station will not answer without the ssid.
?
I am a registered VARA user, and it does not seem to matter if my registration info is in or not.
?
Steps taken:
I have tried a total re-image of the pi and reinstall, and yielded the same results. I have tested my other computer with the radio, and it functions.
?
See log below- running Vara in debug mode:
?
VARA_DEBUG=1 pat http
2024/11/20 21:11:18 my-rig ready. Dial frequency is 7.100.00 MHz.
2024/11/20 21:11:18 Starting HTTP service (http://127.0.0.1:8080)...
[VARA] 2024/11/20 21:12:31.642550 vara.go:192: Connecting command
[VARA] 2024/11/20 21:12:31.643000 vara.go:192: Connecting data
[VARA] 2024/11/20 21:12:31.644548 vara.go:110: writing cmd: PUBLIC ON
[VARA] 2024/11/20 21:12:31.644670 vara.go:115: writing cmd: CWID ON
[VARA] 2024/11/20 21:12:31.644704 vara.go:120: writing cmd: COMPRESSION TEXT
[VARA] 2024/11/20 21:12:31.644722 vara.go:124: writing cmd: MYCALL KM4PVB
[VARA] 2024/11/20 21:12:31.644736 vara.go:128: writing cmd: LISTEN OFF
[VARA] 2024/11/20 21:12:31.644778 vara.go:350: writing cmd: VERSION
[VARA] 2024/11/20 21:12:31.674091 vara.go:259: got cmd: BUSY ON
[VARA] 2024/11/20 21:12:31.805785 vara.go:259: got cmd: BUSY OFF
[VARA] 2024/11/20 21:12:31.805854 vara.go:259: got cmd: OK
[VARA] 2024/11/20 21:12:31.805873 vara.go:259: got cmd: OK
[VARA] 2024/11/20 21:12:31.805878 vara.go:259: got cmd: OK
[VARA] 2024/11/20 21:12:31.805883 vara.go:259: got cmd: OK
[VARA] 2024/11/20 21:12:31.805886 vara.go:259: got cmd: OK
[VARA] 2024/11/20 21:12:31.805891 vara.go:259: got cmd: VERSION VARA HF v4.8.9
2024/11/20 21:12:31 VARA modem (VARA HF v4.8.9) initialized
[VARA] 2024/11/20 21:12:31.805965 transport.go:132: writing cmd: BW2300
2024/11/20 21:12:31 QSY varahf: 7100
[VARA] 2024/11/20 21:12:31.904291 vara.go:259: got cmd: OK
2024/11/20 21:12:35 Connecting to KN4CCQ (varahf)...
[VARA] 2024/11/20 21:12:35.044685 transport.go:132: writing cmd: BW2750
[VARA] 2024/11/20 21:12:35.044745 transport.go:51: writing cmd: WINLINK SESSION
[VARA] 2024/11/20 21:12:35.044772 transport.go:61: writing cmd: CONNECT KM4PVB KN4CCQ
[VARA] 2024/11/20 21:12:35.155423 vara.go:259: got cmd: OK
[VARA] 2024/11/20 21:12:35.155651 vara.go:259: got cmd: OK
[VARA] 2024/11/20 21:12:35.155700 vara.go:259: got cmd: WRONG
[VARA] 2024/11/20 21:13:00.041332 vara.go:259: got cmd: BUSY ON
[VARA] 2024/11/20 21:13:01.001281 vara.go:259: got cmd: IAMALIVE
[VARA] 2024/11/20 21:13:01.456418 vara.go:259: got cmd: BUSY OFF
?