Re: Reset to factory default


 

If you are trying to connect at a baud rate you had set, that is very likley the issue.
When running TeraTerm on poweringthe TT4, you should see the "?" and other boot info.
If not, you probably have the wrong baud rate setting.


As I recall, the baud rate for the bootloader is 19200,n,8,1.
This happens at bootup (before reading settings), so no matter what the settings are in the EEPROM.

Robert Giuliano
KB8RCO


On Monday, April 6, 2020, 12:39:36 PM EDT, Bill Dornbush <bill@...> wrote:


I had a friend's TT4 and couldn't get into it with my null modem cable.? However, I found that the Byonics Serial to USB cable would work with Tera Term on Windows 10 and communicated even when I had set the baud rate incorrectly.? I then could set it to the baud rate I wanted, and could set other parameters as well.
--
Bill Dornbush AA6BD