¿ªÔÆÌåÓý

Re: clock calibrator


 

I have the following:

?

HP 3575A gain-phase meter

HP K34-59991A phase comparator

Tracor 527A & 527E frequency difference meters

?

The 527¡¯s are handy for fast convergence of a significantly off-frequency signal.? Then for fine adjustment both the HP meters are called into use.? The analog output of the 3575A can be fed into a PC for long-term analysis and is handy for setting the crossover point of quartz crystal based standards.

?

Greg