On Mon, Dec 19, 2022 at 6:36 PM G8DQX list <list@...> wrote:
Jeff,
it all depends on what one means by super impressive. The spec is
for an accuracy of 0.1% at 10?V output. Over the temperature
range, that's pretty good. If one requires much better accuracy
than that, then a lot more pomp and circumstance is
necessary, obligatory perhaps.
It's more than good enough to check the DC accuracy of a 3? digit
DVM (or many sampling scopes), and to get one started on a process
to check wider ranges.
And it's way way simpler¡ªand far less of a health hazard¡ªthan a
standard Weston cell! Also a lot cheaper than a modern Josephson
standard.
And best of all, the AD854 chip is probably a recycled pull from
some other equipment. And now one can see just how good 30 and
more years old DVM's can be¡ªa real tribute to the designers' and
various manufacturers' craft & engineering.