Re: Tek 7904 HV transformer T1310 part 120-0742-00 insulation burning
Can you use Kapton tape instead of paper? Jared.
By
Jared Cabot
·
#17023
·
|
Re: Tek 7904 HV transformer T1310 part 120-0742-00 insulation burning
Here is a link to the service manual: https://w140.com/tekwiki/images/1/12/070-1195-02.pdf Here is the link to the transformer winding details I just uploaded:
By
Ananda
·
#17022
·
|
Tek 7904 HV transformer T1310 part 120-0742-00 insulation burning
Hi, My 7904 HV transformer in the PSU is giving trouble. There has been corona type discharge from LV secondary windings and on taking it out the transformer paper is burnt away in places. I guess it
By
Alan Bain
·
#17021
·
|
Re: Tektronix 577 curve tracer not working properly
The 2n5566 jfet was not working properly, the part listed as Q604A in the 177 schematics . I¡¯ll try to change that one and see if the problem will solve. Do you think that this faulty jfet could be
By
Marco Lazzarato
·
#17020
·
|
Re: Tektronix 577 curve tracer not working properly
Thanks for your reply, the calibration and the relative adjustments were done when I brought the tracer home a month ago and it passed all of them. Now the traces are 2 vertical division in the 10 mA,
By
Marco Lazzarato
·
#17019
·
|
Re: Tektronix 577 curve tracer not working properly
One thing to note that is really important on the 577/177 is there is a calibration routine for the 177. This needs to be completed FIRST before the frame (577) calibration will converge. If you are
By
Zentronics42@...
·
#17018
·
|
Re: Tektronix 577 curve tracer not working properly
On Sun, Oct 13, 2024 at 11:07 AM, Dave Voorhis wrote: > > > > I have two 577s and haven't seen your problem, and changing the intensity > pot itself almost certainly had nothing to do with the
By
Marco Lazzarato
·
#17017
·
|
Re: Tektronix 577 curve tracer not working properly
I have a major update, today when i switch throught all the minor vertical/div settings the yellow light of overrange doesn¡¯t light up, when switching by the 50 to 20 and 10 mA i¡¯ve noticed a lot
By
Marco Lazzarato
·
#17016
·
|
Re: Tektronix 577 curve tracer not working properly
I have two 577s and haven't seen your problem, and changing the intensity pot itself almost certainly had nothing to do with the problem. It sounds more like there's been some reassembly blunder or an
By
Dave Voorhis
·
#17015
·
|
Re: Tektronix 577 curve tracer not working properly
The curve tracer was fully operational,i ran through the whole calibration/adjustment steps when i brought it home, than i realized that when I tried to set the intensity the pot was moving but in a
By
Marco Lazzarato
·
#17014
·
|
Re: Tektronix 577 curve tracer not working properly
Do you have a normal looking trace? Those two pots are in very different parts of the circuit. R1245 seems to set intensity, and R528 is in the horizontal offset circuit. Maybe give us some more info
By
[email protected]
·
#17013
·
|
Tektronix 577 curve tracer not working properly
Hi all, i bought a month ago a tek 577 with a few fixtures, tested a few times and it was working but was a little out of spec, so i¡¯ve dediced to do a little calibration and found out that 2
By
Marco Lazzarato
·
#17012
·
|
Tek DPO70804
I have this scope here and it is doing weird things. First thing is when the Diagnostics are run, it displays a couple errors. "Processor" displays Result 114 with 1 Failure Count. "Acquisition"
By
Zack Widup
·
#17011
·
|
Re: Tek 516 6GM8 Tube
There's a ton of them on eBay. Burt, K6OQK
By
Burt K6OQK
·
#17010
·
|
Re: Tek 516 6GM8 Tube
The Tubestore has them for $20 each. That¡¯s not a bad price. https://www.thetubestore.com/6gm8-ecc86
By
Eric Boyle
·
#17009
·
|
Re: Tek 516 6GM8 Tube
I don't know of any equivalents for the 6GM8 or ECC86. It's a special dual triode designed to run at very low plate voltage and the maximum quoted in the datasheet is only 30 volts. If you have a tube
By
Morris Odell
·
#17008
·
|
Re: Tek 516 6GM8 Tube
Try a ECC86 http://www.r-type.org/exhib/aaa1161.htm Dave G8KBV.
By
Dave_G0WBX
·
#17007
·
|
Tek 516 6GM8 Tube
Are there substitutes for this tube ? I che3cked mine on a TV7 tube tester and got 0 reading for transconductance test. I thought the TV7 manual had wrong settings but I think its right. Regards,
By
danadak
·
#17006
·
|
Re: Tektronix 2465A CT issues
Understood. So if you didn't do anything except take it apart and then reassemble it. The most like issue is a cable that is not on right. Very difficult to diagnose that over messages. Also, the
By
victor.silva
·
#17005
·
|
Re: Tektronix 2465A CT issues
Hi, I didn't recap, everything is original.
By
Jorge Andrade
·
#17004
·
|