¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Retubing 545 line amplifiers
When I try to go there I get message from Fox web service about no channels---what is that about paul
By Paul Kraemer <elespe@...> · #34684 ·
Re: AARGHH, Isn't it typical.
As I recall from reading up on this, the fan is not temperature controlled but a burshless DC design running at a constant RPM. I could be mistaken, but I don't remember anything in the manual
By Dave Casey <dcasey@...> · #34683 ·
Retubing 545 line amplifiers
If any of you are thinking of replacing all of the vertical amp tubes (takes quantity 14 as I remember) in you 545 etc. scopes, Antique Electric has the 8136 at a great price right now: 8136 -
By cim <cim@...> · #34682 ·
AARGHH, Isn't it typical.
Hi group. Got my 7854 yeasterday, and guess what the f...g transportation company did. The back of the scope is smashed, with the sheet of metal with the Fan output and the connectors completly
By Tomas <tomaslarssonse@...> · #34681 ·
Re: Looking for leveling head for SG5030
try Deane I think he has a few left jim
By Jim Popwell <jpopwell@...> · #34680 ·
Looking for leveling head for SG5030
The good news is that I fixed my SG5030. The bad news is that I'm looking for a leveling head. Does anyone have or no of one that is for sale? Howard
By Howard Ashcraft <hwa@...> · #34679 ·
Looking for DMM knob for 2337
The 2337 has a DMM in the hinged front cover. There is a range knob that keys onto a narrow diameter 0.159" shaft with a flattened side to match the knob key. Anyone? Thanks, Howard
By Howard Ashcraft <hwa@...> · #34678 ·
Re: TEK 7L14
Chris, The 7L14 Mod 139U or Option 39 as it was later called has its advantages and disadvantages. The big advantage is that the frequency range is extended to 2.5 GHz which these days is kind of nice
By Brian J. Henry · #34677 ·
TEL 7L14
I have a working 7L14, but it is the standard 1.8 GHz model. I have an opportunity to get hold of a 7L14 - 139 modification, which extends the frequency range to 2.5 GHz. However the mod 139 model is
By Chris van Lint · #34676 ·
Re: More Tek 494P GPIB help needed
Hi John, You probably did this, but did you remember to cycle the 494P power off and then on after setting the GPIB dip switches? I think you have to do this to "clock" the switch settings into the
By Stan & Patricia Griffiths · #34675 ·
FS: 11A33
I recently purchased an 11302A that had an 11A33. It passes start-up and extended calibration tests and is in good shape, cosmetically. I already have an 11A33, so I am offering it here for $80 plus
By Howard Ashcraft <hwa@...> · #34674 ·
Re: fan replacement for tek 492/494/496/275xP spectrum analyzers
By a startling coincidence, I just posted a document discussing that very issue, with part numbers: http://www.ke5fx.com/49x_notes.pdf See page 10 for the fan suggestions. If you happen to run across
By John Miles <jmiles@...> · #34673 ·
fan replacement for tek 492/494/496/275xP spectrum analyzers
I am looking for a replacement fan for a 2754P. If I can't find the real part, I have a few questions... How many CFM is the original part rated for? Any thoughts on using a 60MM square 5VDC fan and
By Jim Cotton · #34672 ·
Re: 2445 vs 2465 scopes
you The 2465 display was very poor -- looked as if the trace was "smeared" or being overlaid by multiple traces. I cleaned every plug & socket and checked the PSU voltages (all OK). After spending a
By oldtestgear <philip.parsons@...> · #34671 ·
Re: P6015A HV Probe: Applications?
Sigma Aldrich. Expect around $200 by the time you've bought 100g of it, plus the regulator to screw on the top of the canister. And no - you can't use anything else. Check the archives for details.
By Craig Sawyers <c.sawyers@...> · #34670 ·
TDS 7404
Need calibration software for TDS 7404. Anyone out there have a copy i can get. Or know where I can get one. Obsolete per Tek. David dminesinger@...
By David Minesinger · #34669 ·
Replacement for 466
Hi all, I have had my excellent and reliable 466 for over 20 years and seek to replace it. So I thought that the wisdom of the group might lead me to a good more modern alternative, that won't cost me
By Terry Bicknell · #34668 ·
Re: P6015A HV Probe: Applications?
RE: [TekScopes] P6015A HV Probe: Applications? I just picked up a P6015 which still uses the Freon 114 dielectric. The probe is full, however the recharge can is empty. Does anyone know if the
By dxs4355 <dxs4355@...> · #34667 ·
Re: P6015A HV Probe: Applications?
On Sun, 14 Sep 2008, Craig Sawyers wrote: > > Article 4(1) of Directive 2002/95/EC on the restriction of the use > > of certain hazardous substances in electrical and electronic > > equipment (1)
By Geoff Blake <geoff@...> · #34666 ·
Re: 2445 vs 2465 scopes
wrote: The 2465 the Rather than replacing parts in the 2445, have you considered transfering boards/components from the 2445 to the 2465 to get that working? Comparing the 2 models, many components &
By sukrat2007 · #34665 ·