Re: 475 Triggering Issue -- Will recent 468 Triggering Issue Thread Help Me?
I am a little surprised that the A trigger centering adjustment could
not calibrated that offset out but with Q522 bad, the trigger
sensitivity could have been screwed up anyway.
Do you have any idea
By
David Hess
·
#88133
·
|
Re: 475 Triggering Issue -- Will recent 468 Triggering Issue Thread Help Me?
Good job Stan. Thanks for sharing your results as I am sure someone in the future will benefit from your work.
Regards,
Tom
By
Tom Miller
·
#88132
·
|
Re: 475 Triggering Issue -- Will recent 468 Triggering Issue Thread Help Me?
SOLVED...while pin 3 of U520 had a good copy of the waveform being triggered on, the DC voltage on pin 3 was 1.6v. I found the U520 pin voltages posted by Tom Miller and noted that proper voltage for
By
Stan Katz
·
#88131
·
|
Re: OT: WD40 depressing experience
"ejp286" <esmond.pitt@...> wrote:
Our tax dollars at work!
-ls-
By
teamlarryohio
·
#88130
·
|
Re: OT: WD40 depressing experience
I bought a can last year right off the shelf and it can with an extension
nozzle, nothing else.
What am I missing?
Do I want to know?
Dennis
By
Dennis Tillman W7pF
·
#88129
·
|
Re: OT: WD40 depressing experience
Where the heck do you live? Wouldn't it have been easier to just buy it
locally?
By
Shirley Dulcey KE1L
·
#88128
·
|
Re: OT: WD40 depressing experience
Don't worry, you'll have plenty of time to read them all in the */next/* forty years.
Don Black.
By
Don Black <donald_black@...>
·
#88127
·
|
OT: WD40 depressing experience
I had a depressing experience last week. I bought my 2nd can of WD40 in forty years. (Yes I don't spray it on everything and that's why the can lasted 40 years.) First can was bought over the counter
By
EJP
·
#88126
·
|
Re: 465M blows internal .25A fuse
Hello,
I keep trying to isolate. I finally after lifting connections 8, 9, and 10 from T550, am able to turn up the variac without blowning the 1/4 amp fuse. 95 volt test point reads 135vdc. If I only
By
Bob
·
#88125
·
|
Re: New here with a 2465 to clean up
1 wire temp sensor
By
Gala Dragos
·
#88124
·
|
Re: Tektronix TM500 Extender Cable
Dave,
The pins for custom signal connections could be ignored in an extender
cable. Those pins are to allow the user to interconnect the rear
in/outs between plugins.
For ex, you could take the
By
HankC, Boston, WA1HOS
·
#88123
·
|
Re: New here with a 2465 to clean up
Great piece of temperature measurement by Patrick.
The grp can consider two ways to measure the temp with cover on:
1. Use a good thermister- EPCOS B57862S282A9 Miniature Bead Thermistor. Not
so
By
cslim388
·
#88122
·
|
Re: Which Tektronix Signal generator?
I have a 8660C which I use frequently. One of the plugins will allow you to go down to 10 kHz, another up to 2.6 GHz and that is very nice. Yes, these are very heavy. I found that mine (and apparently
By
Peter Gottlieb <hpnpilot@...>
·
#88121
·
|
Re: Which Tektronix Signal generator?
I have an HP 8660D which I like. It uses plug-ins and will generate signals up to 2.6 GHz with the right plug-ins (and the 11661B optional frequency extension option). I also have a couple of 8660Cs
By
Dave Daniel
·
#88120
·
|
RES: TR503 up for auction
Hi Gordon,
I am in Brazil and would like to BID on the TR-503. Can you ship to me in
Brazil?
If this is OK, I will put some bids, but ebay say that "Th=e selle cant send
oversea".
Please,
By
Marcus - PP5MS
·
#88119
·
|
Re: Which Tektronix Signal generator?
I have the 8642B and highly recommend it. 100 kHz to 2.1 GHz range. Extremely high quality CW, AM and FM signals. Frequency sweep capability. It is quite heavy, though.
The 8648 models are newer,
By
honolulusnowwhite
·
#88118
·
|
465M blowing a fuse
Oh boy.... well, OUR starting point fix for these scopes is to re-cap all of the LV caps... Take the cans off the board, re-stuff, and replace..... Got to start somewhere ! Our experience with these
By
Ashley40@...
·
#88117
·
|
Re: New here with a 2465 to clean up
I'm with the school of thought regarding not stressing U800 mechanically, so I used this particular heat sink. One thing nice about the 2465A/2467 generation is that they still have
By
honolulusnowwhite
·
#88116
·
|
Re: 465M blows internal .25A fuse
Hello,
Finally got back to repairing my 465m scope. Still can't figure why I'm blowing the 1/4 amp fuse. I powered up the scope with a variac and increased the unreg 32 volts to 20 volts before
By
Bob
·
#88115
·
|
Re: Which Tektronix Signal generator?
Two points .... first, you need to get a unit with Option 002* installed. ?This option gives operation from 512 MHz to 1024 MHz. ?Without it, the generator will INDICATE the higher frequencies, but
By
Jim <n6otq@...>
·