¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Tek 2236 scope repair
Does anyone know what the power supply should draw when connected to an external power supply? At 40 volts my power supply is drawing a little over 1.2 amps.
By Board · #203470 ·
Re: Tek 2236 scope repair
The 2200 series have problems with the rectifier diodes going bad on the secondaries. Use something like 1N4937 diodes as replacements. A very fast or higher speed is necessary as replacements. The
By Mark Vincent · #203469 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
Yeah, that is another possibility. Thanks, Mac. Jim
By Jim Ford · #203468 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
Yes, the opportunities for creativity are endless! Thanks for the ideas, Dave! Jim
By Jim Ford · #203467 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
I just saw some TM-5xx rigid extenders on ebay for $60. Item # 223811718800 . DaveD
By Dave Daniel · #203466 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
Well, perhaps you can disguise them as picture frames for your wife's favorite pets or flowers or something when they're not in use in the lab. You could even put LEDs in to light the photos. Or use
By Dave Daniel · #203465 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
The TM515 power supply assembly, which includes the backplane with the connectors for the modules, can be easily removed from the frame by removing the obvious screws on the rear panel. With a few
By Mac Perkins · #203464 ·
Re: Tek 2236 scope repair
Increasing the intensity increases HV PS drain, which is causing the HV to sag. Reduced HV expands the trace. So, yup, you've got PS troubles. Look first at the usual suspects (e.g., bad bypass caps
By Tom Lee · #203463 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
Ah, a TM501 and a TM502, in addition to a larger one to hold multiple plug-ins.? The wife is going to LOVE that idea!? Thanks for the inspiration, Dave!? LOL!? ? ? ? ?Jim?Sent from my
By Jim Ford · #203462 ·
Tek 2236 scope repair
Hi, I found a Tek 2236 scope in the garbage. After running it for a few minutes, the power supply failed. Powering the scope from a 42 volt supply caused the NPN transistors to fail. I replaced the
By Board · #203461 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
For DIY, give a try to my own very project: https://github.com/anotherlin/tek_tm_ext Here are some more photos: /g/TekScopes/album?id=243643
By Ke-Fong Lin · #203460 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
Zenwizard has a 2 slot unit he's using for open access.?? You'd need the TM5002, of course. Harvey
By Harvey White · #203459 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
You'd probably want to use the smallest TM module in which the plug-in will fit. That way one can get to three sides of the plug-on. I have a TM-501 dedicated for troubleshooting single-bay plug-ins.
By Dave Daniel · #203458 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
Depending upon where the fault(s) is, you will certainly need three full-size extender cables and one daughter cable: I encountered just this situation when repairing a CG5001. I have some images of
By Shaun M · #203457 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
Hmmmm.... The "remove the sides" trick probably won't work on a TM515 portable like mine, though.? Darn, I guess that means I'll have to scout for a TM506 or TM5006 or a smaller TM50X mainframe.?
By Jim Ford · #203456 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
Dave Daniel¡¯s suggestion regarding access to the innards of the plug-in via removal of the side covers of a power supply module works very well providing that what you are after is accessible via
By Greg Muir · #203455 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
You really should have asked for some advice here before hacking into that CG5011. The encoder with a broken shat is repairable - you shave off the plastic ends of the posts clean up internally and
By victor.silva · #203454 ·
Looking for P6022 lower body half PN 204-0362-02
From pages 34/ 35 of the P6022 user manual: 204-0362-02 BODY "ASSY,PROBE:LOWER" And the user manual is here: https://w140.com/tek_p6022.pdf This is the lower half of the body shell that does not
By Alex · #203453 ·
Re: Extender Cables for TM500/5000 series - Alternatives?
You'll almost certainly need to make an extender for the individual boards in the CG5011 as well as having extenders to connect to the TM5000 frame. See e.g.
By David C. Partridge · #203452 ·
Re: Tektronix 2252 - Single Sweep Mode / Storage Mode
You would probably get much better mileage and exposure from your sales offer if you do it in a separate dedicated posting. Good luck with the sale.
By Alex · #203451 ·