¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Temperature coef nomenclature
Dear All, I am trying to fix a Tek 577 for some time. After a LOT of work I think I have been able to fix all major problems of the unit and go through the calibration procedure. One minor issue I
By Rogerio O · #192542 ·
Re: 744a
I remember when I was in that situation, Facebook Marketplace cured that symptom. Anyways, amazingly there are many that might be in your local area that don't advertise the best that might even
By nonIonizing EMF · #192541 ·
Re: Fixing a PS502 that blows the fuse in the TM500 power module
Murchison, I thought that I had checked the bridge rectifier (CR10) for shorts, but either I had not, or I had not made good contact when doing so, because now I see that two terminals are
By Jeff Dutky · #192540 ·
Re: Fixing a PS502 that blows the fuse in the TM500 power module
Have you checked CR10 for shorts?
By Merchison Burke · #192539 ·
Re: 547 HV Transformer Question(s)
I didn¡¯t get to that point yet. I¡¯m getting ahead of myself. I was just monkeying around with R544 and R566 to see if they had any effect. Many things were bad in this scope. I changed several
By Stephen · #192538 ·
Re: 547 HV Transformer Question(s)
Hi Stephen, Which pots do you mean? Sweep lenghts are determined by internal trimpots in the Miller run-up circuits, calibration steps 24 and 44. Is time/div OK or also expanded? Albert
By Albert Otten · #192537 ·
Re: 547 HV Transformer Question(s)
Hi Albert, Will do. Thank you
By Stephen · #192536 ·
Re: 547 HV Transformer Question(s)
On Wed, Apr 13, 2022 at 01:00 AM, Brenda wrote: Hi Brenda, Interleaved. > Hi Steven, > > I do not have a 547 yet myself, but from what I have read is that one of the > main signs was that the
By Stephen · #192535 ·
Re: 547 HV Transformer Question(s)
Search or "547 V800". Albert
By Albert Otten · #192534 ·
Re: Fixing a PS502 that blows the fuse in the TM500 power module
Oh, sorry: it is a PS502, dual tracking supply plus fixed 5 V supply. Fairly empty inside. Here¡¯s the TekWiki page https://w140.com/tekwiki/wiki/PS502
By Jeff Dutky · #192533 ·
Re: Fixing a PS502 that blows the fuse in the TM500 power module
PS502 or PS503? You've said both.
By EJP · #192532 ·
Fixing a PS502 that blows the fuse in the TM500 power module
I've got this PS502 that I've been trying to fix literally for years. I got it as a set with a TM503 + DM501 and DC503 from the surplus outlet of my local university (when I was still close to a
By Jeff Dutky · #192531 ·
Re: 744a
Yes like those. I wish I had a printer
By mystic96 · #192530 ·
Re: 547 HV Transformer Question(s)
Hi Steven, I do not have a 547 yet myself, but from what I have read is that one of the main signs was that the trace would dim out making you turn up the intensity until the trace gets really dim
By Brenda <brendda75@...> · #192529 ·
547 HV Transformer Question(s)
I¡¯m wondering what are the symptoms of a bad or failing HV transformers in these scopes. I¡¯m still awaiting for some more tunnel diodes to arrive (2.2mA and 4.7mA), but the trace is not very
By Stephen · #192528 ·
Re: 465 non A or B Delay Time Position has no effect
I second Ozan's comments about the A+ and B+ gates (Top two BNC's on rear panel). You can connect these outputs to another scope and observe the action of the gate signals, This will tell you a lot
By Michael W. Lynch · #192527 ·
Re: 465 non A or B Delay Time Position has no effect
I added a picture of gate signals at back BNCs from 485, I don't have a 465 but I expect waveforms to be similar in delayed B mode. /g/TekScopes/photo/262059/3414406 Ozan
By Ozan · #192526 ·
Re: 465 non A or B Delay Time Position has no effect
My comments are inline. I believe 465 has A-gate and B-gate BNCs on the back. If you look at both A-gate and B-gate on your 485 you can tell when A-sweep is running and when B-sweep is ru
By Ozan · #192525 ·
Re: 465 non A or B Delay Time Position has no effect
Ok. A sweep...? normal sweep controlled by A timebase.? No intensified sections. A intensified by B:? precisely what it says.? A timebase. Brighter segment representing the B timebase interval
By Harvey White · #192524 ·
Re: 465 non A or B Delay Time Position has no effect
OK, I¡¯ve done some more reading¡­ I know the ¡®B¡¯ time base is being delivered to the sweep amplifier because when I switch the HORIZ DISPLAY to B DLY¡¯D I can see my test signal on the screen
By Michael - AF7U · #192523 ·