Re: Tek 2467b test 05 error
Excellent point, Artekmedia. I'll know soon enough! -Stefan
By Stefan · #150556 ·
Re: Tektronix 465,NO Trigger
Well Success at last Fabio !!!!! I did not realize that the FET's were in sockets under the heatsinks, I decided to change them and I still had no Trigger, as they were out I tested the FETt's on my
By John Stoole <john@...> · #150555 ·
Re: TEK 466 Analog Storage
This should be covered in the service manual: e.g. https://docs.telegraphics.com.au/Tektronix_070-1753-01_466_Storage_Oscilloscope_with_option_Service_Instruction_Manual_Revised_Nov_1982.tif
By toby@... · #150554 ·
Looking for ...
120-1087-00 transformer or complete HV module for a 7603. Chris
By W9RP · #150553 ·
TEK 466 Analog Storage
Hi all, I've finally got a mo to look at the 466 I bought sight-unseen a while ago. I'm not really familiar with analog storage scopes, though. I've been given to understand that after switching on
By Paul B. · #150552 ·
Re: Concentric A and B time-base knobs/interlocking
Interesting... Raymond
By Raymond Domp Frank · #150551 ·
Re: Tek 2467b test 05 error
Also in this day and age it is not sufficient to look at the just the unit serial number. There are so many organ transplant units floating around where a previous? owner swapped an early A5 in a
By Dave / NR1DX · #150550 ·
Re: Tek 2467b test 05 error
As Siggi has mentioned, the A5 board (processor control) is a frequent source of failure in these scopes.? But Tektronix went through several design iterations of the A5 board over the years
By machineguy59 · #150549 ·
Re: Tektronix 465,NO Trigger
Good morning John, Yey! Seems like you've made some progress there! A reading of -7.9V on the pins 2,3 of U460 is not normal, if the input is set to EXT and the input jack is grounded... the output of
By Fabio Trevisan · #150548 ·
Re: Concentric A and B time-base knobs/interlocking
I had a flash of inspiration over this; I wondered if the Z-axis modulation was functioning properly. I tried putting a sine-wave into the CH1 vertical and a square-wave into the external Z input.
By Colin Herbert · #150547 ·
Re: Tektronix 465,NO Trigger
Good Morning Fabio, I have carried out the tests to the U640 as you suggested for both the A trigger and the B trigger here are the results A TRIG 14/15 20.4 mv 2/3 -7.9 volts !!!!!!!!!?????? B TRIG
By John Stoole <john@...> · #150546 ·
Re: Tek 2467b test 05 error
Thanks guys for the responses. I'm definitely new to scope repair. The 2467 could not be passed up but it did come with the faults when I purchased it. I do have an inexpensive digital scope that I
By Stefan · #150545 ·
Re: tektronix 214 option 94/ Li-Ion fork
I wouldn't pick to much on Li-Ion chemistry. There are a lot of deployed chemistries and construction methods. Some have problems some don't, just like NiCd & NiMH. I've seen plenty of NiCD rotting in
By Kevin Oconnor · #150544 ·
Re: Is it possible to get an eye diagram on a TDS784?
Well an eye diagram is really just the envelope of all hi/lo & early/late levels & transitions in a data stream. Assuming that you can trigger off something relative to the stream, even old scopes
By Kevin Oconnor · #150543 ·
5A18N and 5403 manuals free for postage
Hi, everybody. I ended up with these 5A18N and 5403 manuals when I bought my 5110 scope a few months ago. Came with two 5A15N's and a 5B10N, but those manuals obviously don't apply. Let me know where
By Jim Ford · #150542 ·
Re: TG501 20ns 10ns 5ns
Thank you Fabio. I'll have a closer look at the TG501 over the next few days - unfortunately its difficult to access any of the components on the main board without first removing the multiplier board
By Kerry Burns · #150541 ·
Re: User Groups
http://groups.yahoo.com/group/hp_agilent_equipment/ The group is in the throws of getting ready to move to Groups.io but for now is on Yahoo groups -DC NR1DX manuals@... -- Dave
By Dave / NR1DX · #150540 ·
Re: tektronix 214 option 94
Hi Miguel, This is the reply I got from Hakan: Dennis, I had a look again and I also went through all the 200 scopes and still not a trace of Opt 94. 214, and some of the other, has a several Customer
By Dennis Tillman W7pF · #150539 ·
User Groups
Dear All. Sorry this is off topic, but is there a similar user group to this one for for HP signal generators etc. Regard. Ken Wright??? M0KHW
By Ken Wright <kenwright309@...> · #150538 ·
Re: tektronix 214 option 94
On Fri, 17 Aug 2018 14:20:02 -0700, you wrote: >Hi Jim, >I concur about the Nickle. It isn't worth its weight in nickel. > >NiCd rechargeable cells have many advantages over Li rechargeable cells as
By Harvey White · #150537 ·