Re: Tektronix 453 Power Indicator Bulb needed
Sphere says they have 3 new in stock T1 Based Lamp 150-0045-00 Incandescent Lamp T-1 miniature lamp with base. New in factory bags. 3 New $5.00
By
Brendan
·
#148976
·
|
Re: FS: Tektronix scopes on craigslist; North of Boston, MA
I picked up a 7844 from this seller last week. He's a nice guy and clearing out a scope rehab hobby, apparently. -- Phil wrote:
By
Phil Genera
·
#148975
·
|
Problematic Tek 7A26 Vertical Amp
I have a 7A26 vertical amp unit that is misbehaving. It is housed in a Tek 7704A. A borrowed (good) 7A26 operates correctly. The symptoms are as follows: (1) The amplitude of a given signal does not
By
k6whp
·
#148974
·
|
Re: Up to date capacitor list for Tek 2465A and 2465B scopes (2018)
Hi Menahem: I should place the illinois capacitor link for comparison to the Nichicon . You'll see for the 50V, 2200uF cap I am using the KXM series (which I use mainly now) has much better ripple
By
Ancel
·
#148973
·
|
Re: using scope channel 1 and channel 2 invert and add functions vs floating DUT
Thanks for the comment Steve ! I look forward to that document posting. Good point on the common mode resolution limitation. A question in regard to the CMRR, is the poor response a function of the
By
[email protected]
·
#148972
·
|
Re: using scope channel 1 and channel 2 invert and add functions vs floating DUT
Thanks Dennis, I just downloaded it. I'll look at it. Thanks for the comment.
By
[email protected]
·
#148971
·
|
Tektronix 453 Power Indicator Bulb needed
I am looking for one B1107, 'Power On' indicator bulb, for the Tektronix 453 that I am trying to fix. The Tek part number is 150-0045-00. Does anyone have one that they would like to sell me or can
By
Michael Gladu <n1fbz@...>
·
#148970
·
|
Tek 49x -- Power Supply Replacement Capacitor List
Has someone compiled a list of the capacitors to replace in a Tek 49x series power supply? I seem to remember seeing such a parts list in the past, but do not readily see how to search the archives
By
ebrucehunter
·
#148969
·
|
Re: 465 bad rise time
Im using a 50ohm cable a 50ohm through termination and a pg506 fast rise pulse.
By
Brendan
·
#148968
·
|
Re: 465 bad rise time
What is the source of the signal being displayed ? What kind of probe is being used ?Is it compensated ??Is the probe ground lead connected ? Do yourself a favor & lose the probe.Connect to a decent
By
HankC, Boston, WA1HOS
·
#148967
·
|
Re: Up to date capacitor list for Tek 2465A and 2465B scopes (2018)
Hi Ron, I wonder if we may know each other. I knew a Ron who would be about your age who ran an engineering organization in Cedar Rapids. At the time, I was a brash young engineering group manager in
By
Jeff Davis <n0dyjeff@...>
·
#148966
·
|
Re: 465 bad rise time
Sorry Raymond, again I missed you message of a few minutes ago! BTW I sold my one and only 465 some time ago, so I can't help with doing measurements. Albert
By
Albert Otten
·
#148965
·
|
Re: 465 bad rise time
They share the same output amplifier.
By
Albert Otten
·
#148964
·
|
Re: 465 bad rise time
The vertical output Amp and some other parts, like parts of the channel switch, are common. Raymond
By
Raymond Domp Frank
·
#148963
·
|
Re: Self Governance of TekScopes.
In the end, it is the moderator's responsibility to determine how he or she wished to have the list moderated. I this case, Dennis has laid out how he wishes the list to be moderated. DaveD
By
Dave Daniel
·
#148962
·
|
Re: 465 bad rise time
On Mon, Jun 18, 2018 at 04:41 am, Raymond Domp Frank wrote: > > On Mon, Jun 18, 2018 at 04:23 am, lop pol wrote: > > > > > I will start turning screws. I just wanted to get opinions on whether this >
By
Brendan
·
#148961
·
|
Re: 465 bad rise time
You have the proper fast rise generator to perform an adjustment. The risk in my opinion is that you destroy a stuck trimcap or trimpot. You might first verify DC levels in the output amplifier stages
By
Albert Otten
·
#148960
·
|
Re: Self Governance of TekScopes.
I would think that it's the moderator's responsibility and no one else (elders or otherwise) to filter the various threads. There are certain topics that are completely off topic like politics and
By
JJ
·
#148959
·
|
Re: 465 bad rise time
Before you start turning screws: 1. It is not uncommon for the variable caps to become open. I've had that happen to some in the vertical (output) amplifier. I've seen both the rotor not moving *and*
By
Raymond Domp Frank
·
#148958
·
|
Re: 465 bad rise time
The BW limit switch is off. Turning it on increases the rise time and smoothed the trace like I would expect. verify the setup. Yes but i checked the setup with my 468 (100 mhz) and the rise time was
By
Brendan
·
#148957
·
|