开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育
Date
Re: 7603 working .... then blank
R875 1ohm in +50v Supply, Vdrop of 0.22v ….. could this indicate a max current before the Supply turns off????? Absolutely! The current limit threshold looks to be around 200mA or 200mV across
By Dave Hills · #144882 ·
Re: Parts kits/transistors
Try here. Not a lot of different part numbers, but a good range of voltage / current / power. Also includes diodes. This is a “semiconductor kit” with transistors and
By dnmeeks · #144881 ·
Re: 155-0035-00
Hi, Tek 7S12. Thanks.
By gsl@... · #144880 ·
Re: 5L4N Spectrum not Analyzing
I had a few minutes to check it with a lower input signal. I was overloading it. As long as I drop the input down to -10 to -12db the signal all the way down to the L-pad relay is undistorted. The
By Rick · #144879 ·
Re: Tek 2465a grid bias and brightness problems
Thanks Fabio, I am mistaken then, I have suspected that since brightness and readout intesity controls both work, readout is less bright than traces and can be completly turned off, however a part of
By Francesco · #144878 ·
Re: Calibration Fixture Catalog after 1980
David Hmmmm . .... Takes less than a second here using either Firefox or Chrome. Not sure what the "fast page" /"slow page"? thing is about cant tell the difference here. Chrome has been doing wonky
By Dave / NR1DX · #144877 ·
Re: Tek 2465a grid bias and brightness problems
Hello Francesco... Sticking up my nose here so, Chuck who has been on the lead on this thread has the final word but here is my 2?. IIRC your original description of the problem and if the readout
By Fabio Trevisan · #144876 ·
Re: Calibration Fixture Catalog after 1980
Firefox
By David C. Partridge · #144875 ·
Re: 7603 working .... then blank
Roger, Dave, et al, Slow response is no problem to me. I am appreciative of anyone spending their time to help. This process for me is just as much about learning the circuitry as it is about
By tinkera123 · #144874 ·
Re: Tek 2465a grid bias and brightness problems
Chuck I have taken your suggested measurements, since everything up to U950 seems to be working and VQ OUT and VZ Out waveforms are very near to the ones in the service manual, before ordering and
By Francesco · #144873 ·
Re: Calibration Fixture Catalog after 1980
Zero problems from this part of the UK. I suggest a traceroute and/or a different browser and/or temporarily disabling browser settings. It is almost certainly irrelevant, but I did once find a very
By Tom Gardner · #144872 ·
Re: Re-introduction to the group
Your own Electron Microscope? How cool but how on earth do you fit it in a house? This is just the EHT supply for the one in the Cavendish Labs in 1967 and no, that's not me, that's my colleague
By Adrian Nicol · #144871 ·
Re: Can we talk safety for a moment?
I'm jumping around this topic and addressing things here and there. Not necessarily this particular post. There are some loose terms being thrown around about the NEC that need to be clarified. I am
By [email protected] · #144870 ·
Manuals for Sale
All - I'm trying to de-clutter my lab space and have the following original Tek manuals to offer: 556 605 2215 Operators 2215 Service 2236 Operators 2335
By Dave Casey · #144869 ·
Re: Can we talk safety for a moment?
Chuck, I got a little busy after I posted stuff that you objected to. A couple of things you said I would like to address. I posted about things that others had not said already. you said; "Anyone
By [email protected] · #144868 ·
Re: Tek High Amplitude Pulse Generator TM500 manual needed
Hi Ed, The GR Connectors were for the charge line to extend the pulse. They were only on the earliest version of this. That was the first one I listed of the four different versions. The last two
By Dennis Tillman W7pF · #144867 ·
Re: Calibration Fixture Catalog after 1980
TekWiki is never slow when I connect to it. Dennis Tillman W7PF
By Dennis Tillman W7pF · #144866 ·
Re: Pictures
link is bad
By C Smith · #144865 ·
new member intro for Trey Greer
Hello All, I've been lurking in the group, on and off, for years. That's been fun, thanks! I have a collection of old 500 series scopes and plugins that I collected about 15 years ago at hamfests.
By Trey Greer · #144864 ·
Nominal 547 Trigger Jitter
Hey everyone, I've been trying to characterize the trigger jitter on my 547 and I'm not entirely sure what to expect. I've fed a 30 MHz square wave into the ext-trigger input of the A (B) sweep and
By thespin@... · #144863 ·