Re: OT: Triplett 630-NA (was 465B Focus Troubleshooting)
Well,since we're telling VOM stories and talking about battery leakage.... Here's my story and I'm sticking to it!
I have an OLD RCA VoltOhmist. I hadn't used it (or even thought about it) in
By
Steve D
·
#126376
·
|
File - Posting Rules
Welcome to TekScopes. If you're a new member, please introduce yourself to the group. Tell us your interests. Regale us with your Tek stories and collection.
Please edit replies to the list to
By
TekScopes@...
·
#126375
·
|
3D eraser
Last year I purchased the second generation USB compatible carbide tipped stone tablet input device, because I use up pencils only slightly faster than erasers, and the "undo" feature was a "must
By
Trevor
·
#126374
·
|
TM500 DC505A power problem.
from Tim P (UK)
I have a DC505A which appears to have a shorted power rail somewhere. It blew the main fuse in a TM501. I cannot get into it as it is so tightly packed, with the power components being
By
Tim Phillips <tim@...>
·
#126373
·
|
Re: UK practical help with pulse generator
Gordon,
I'm in Swindon and will happily look at it using my 7104 scope, if
that is going to help.
Regards,
Norman
By
Norman Thompson
·
#126372
·
|
UK practical help with pulse generator
Hi. I'm hoping someone in the UK can spare the time to give me a little practical help with a pulse generator. I don't have leveled oscillators, standardizers etc, and generally only very occasionally
By
Gordon <tekscopes@...>
·
#126371
·
|
Re: 5440 low-voltage power supply
Be careful measuring the 6.3 volt filament voltage; it is held very
close to the -3000 volt cathode voltage by R418.
You can check that the HV oscillator is operating by measuring the AC
voltage at
By
David Hess
·
#126370
·
|
Re: Introducing myself and my Tek 465 Project
The situation with the custom ICs is not all that bad. They very
rarely fail and replacements can be found.
I would sure try to diagnose any problem which caused the IC to fail
though. Install a
By
David Hess
·
#126369
·
|
Re: What is the function of Q3005 in the TM506A?
The manual says it should work in the mainframes which lack the power
good signal so I wonder if something else is going on with either the
mainframes or the SG5010.
By
David Hess
·
#126368
·
|
Re: Tek 2440
This should not happen unless there is a DC imbalance in the input
circuits. The self calibration command which can be run after the
oscilloscope warms up for 15 minutes is suppose to remove any
By
David Hess
·
#126367
·
|
Re: Tek 2440
I replaced one of these caps last year in order to get the scope working
at all.
It's almost certainly LVPS switching noise I'm seeing.
Is it time for E=mc^2? (Efficiency = mass cap change)
Yeah.
By
Jeff Woolsey
·
#126366
·
|
Re: Tek 2440 ripple, grat illum inop
I want to say no. The answer will, of course, determine where it's
being injected.
It doesn't seem to change the amplitude of the ripple, but it does
displace the trace vertically (usually downward)
By
Jeff Woolsey
·
#126365
·
|
Re: 7904 plug-in connector contacts
Hi Ed,
Congratulations. I have always thought it would be next to impossible to
replace one or a few contacts. Your post gives me hope.
Dennis Tillman W7PF
By
Dennis Tillman W7pF
·
#126364
·
|
7904 plug-in connector contacts
The recently fixed 7904 (PS problems) that also had no readout in the A-horizontal is now fixed, readout-wise. Replacing the individual contacts on the connector was not that hard to do, except for
By
Ed Breya
·
#126363
·
|
Re: OT: Triplett 630-NA (was 465B Focus Troubleshooting)
Well, now I have to tell my VOM story. Many years ago, I had collected some nice old Weston brand VOMs for cheap - they had the ohms range burned out for the usual reason. So I'd fix that part and
By
Ed Breya
·
#126362
·
|
Re: Introducing myself and my Tek 465 Project
Most of the cap reliability problems are with dry tantalum varieties. These were popular in the 1980-90s because they offered much higher capacity per unit volume than aluminum electrolytic
By
ditter2
·
#126361
·
|
Re: OT: Triplett 630-NA (was 465B Focus Troubleshooting)
--------------------------------------------
By
jim <ab7vf@...>
·
#126360
·
|
Re: Tek 2440
AFAIR, the LVPS +5 V output uses a pi filter (2 C's to gnd, 1 L between them). Did you check / replace all (output) caps in the LVPS? It may be remaining LVPS switching noise feed-through you're
By
Raymond Domp Frank
·
#126359
·
|
Re: OT: Triplett 630-NA (was 465B Focus Troubleshooting)
I just found a post over on the antique radio forums that said if you have to clean the contacts to not spray the phenolics with deoxit as it can ruin the calibration of the ranges. Well....what's
By
John Clark
·
#126358
·
|
Re: OT: Triplett 630-NA (was 465B Focus Troubleshooting)
My first multimeter was a Triplett 630-APL, the mirror scale version.I ordered it with the padded leather case, cost me $65.00 in about 1963 0r 64.I still have it and it works.?Leon Robinson ??
By
Leon Robinson
·
#126357
·
|