Delta Standard for 130 L-C Meter has MINUS 3pF setting
How did Tek get the Delta Standard for the 130 L-C Meter to have a 0pF and a MINUS 3pF value? Exactly what is a negative capacitance and what is it good for? See attached photo. Dennis
By
Dennis Tillman W7pF
·
#88307
·
|
Re: Tektronix 2465 Ch2 dead
The outputs from the U140 and U150 shift registers control more than the attenuator relays. The outputs can change after the relays are activated by the strobe signal from U130G without affecting the
By
David Hess
·
#88306
·
|
Tektronix 2465 Ch2 dead
Hi Guys ! I need a little help to fix my scope. Ch1 is working fine, diagnostics is OK. No signal comes out Ch2 attenuators - testpoint 11 If I set the input attenuators to 1V/Div and compare U140 and
By
pecska
·
#88305
·
|
Re: 466 Trigger on <1Hz Square Wave?
Cliff, ? It sounds like your trigger point is close to the baseline and triggering on noise.? ? ? Here is a round about way to set the trigger point, assuming that your 5V p-p signal will fill
By
xyzzx_adv
·
#88304
·
|
Why no fan?
If you've wondered why some TE have no fan: <http://www.eevblog.com/2013/02/20/eevblog-426-hp-3457a-multimeter-teardown/> Start watching around 19:55 time. Dave
By
Dave C <davec2468@...>
·
#88303
·
|
Re: 466 Trigger on <1Hz Square Wave?
I have it set to normal mode, I've tried both AC, DC, and HF reject couplings, and the channel itself is coupled DC. But it still seems to only want to trigger on the little bit of ripple on the wave,
By
Cliff White
·
#88302
·
|
Re: Could please any one give a clue about this nice pulsed line generator??
I would have used different connectors just to prevent getting the output and the charge line mixed up. <iglesia_cristiana_arpas_eternas@...> wrote:
By
David Hess
·
#88301
·
|
Re: Could please any one give a clue about this nice pulsed line generator??
Yes David I agree , I just wonder me why BNC was a good choice for output pulse, but not for transmission line extender, since both are on the same power and rise time stress...??? Gabriel.
By
iglesia_cristiana_arpas_eternas
·
#88300
·
|
Re: 466 Trigger on <1Hz Square Wave?
Cliff, Use DC, not AC coupling for the trigger. Single-sweep mode would be good too; just press the button whenever you want to update the trace. HankC, Boston WA1HOS
By
HankC, Boston, WA1HOS
·
#88299
·
|
067-0587-01 7k calibration plug-in for sale
Hi, I have a working calibration fixture that I have modified with a modern RP-SMA output connector for the TRIG OUT. I include a female BNC to to RP-SMA male adapter cable about 9 inches long. Asking
By
jerry massengale
·
#88298
·
|
Re: 466 Trigger on <1Hz Square Wave?
Set trigger mode to Normal not Auto. Dave ________________________________ Sent: 02 March 2013 04:13 To: TekScopes@... Subject: [TekScopes] 466 Trigger on <1Hz Square Wave? I have a case
By
David C. Partridge
·
#88297
·
|
Re: 466 Trigger on <1Hz Square Wave?
You can absolutely trigger on low frequency signals including slow ramps. Be sure to set TRIG MODE (below the time/div control on the right side) to NORM instead of AUTO to prevent the sweep from free
By
David Hess
·
#88296
·
|
Re: 2901 Time Mark Generator Case Fixings
Well glad it worked out. They sure look similar. Wish my method would have worked for you. I don¡¯t/didn¡¯t want to make it sound trivial as it takes some work to get it all aligned right and
By
Rob <rgwood@...>
·
#88295
·
|
Re: 466 Trigger on <1Hz Square Wave?
Cliff, I see no reason why you can't set up the trigger to a low frequency wave.? It works fine on every Tektronix 'scope I have ever used. Use the internal trigger, set it for dc, and with a higher
By
Bob Albert <bob91343@...>
·
#88294
·
|
466 Trigger on <1Hz Square Wave?
I have a case where I need to use my 466 to view a /very/ slow (less than one Hertz) 5 volt p-p square wave. Is it possible and/or easy to make it trigger on such a signal? By using the storage mode I
By
Cliff White
·
#88293
·
|
Re: First post - 2465A on the way
go here: http://elektrotanya.com/tektronix_2465a_2467.pdf/download.html
By
cslim388
·
#88292
·
|
Re: Could please any one give a clue about this nice pulsed line generator??
I should have said GR-874 to BNC female adapter. I suspect the adapter will be better than using a questionable Chinese panel BNC. <iglesia_cristiana_arpas_eternas@...> wrote:
By
David Hess
·
#88291
·
|
Re: 2901 Time Mark Generator Case Fixings
Hi Rob, Many thanks for your further reply and, yes, what you used are what we call circlip pliers but there's no way the pliers I've got here would be strong enough to use with these fittings. I
By
poldhu1901@...
·
#88290
·
|
Re: 549 with compresssed trace on right third of screen
I wanted to add: I get the same basic waveform at R341/V343 when selecting either A or B timebases. Also, neon lamp B171 is _not_ lit - should it be? Keith
By
keithostertag <keitho@...>
·
#88289
·
|
Re: Could please any one give a clue about this nice pulsed line generator??
Thanks Dennis, as soon put my hand on this nice gear , I will consider buy from you the adapter!. Gabriel.
By
iglesia_cristiana_arpas_eternas
·
#88288
·
|