Re: Patch cable for 7S12 015-1017-01 (750 pS)
One of the firsts things that you can check is the big difference beetween cheap and expensive 50 ohms load resistors, then you can measure if they are inductive or capacitive at high frequencies.
By
Miguel Work
·
#189130
·
|
Re: 5111A Horizontal BW limit.
Dave, Have you made any progress on this? It¡¯s bugging me. I saw suggestion (in another group) that oxidized contacts could add capacitance to a circuit. I¡¯m not sure that there are any candidates
By
Jeff Dutky
·
#189129
·
|
Re: 7704A, good deal?
Commenting on your photos is not easy because we don't see the whole story. The V-A, H-B picture showing the pulser output looks like what I would expect. On the "20 mV 50 ps" picture with the fast
By
Peter H
·
#189128
·
|
Looking for 506
I would like to acquire a Type 506 scope with 9A1 and/or 9A2 plug-in. Prefer one that shows a trace! If you would like to get rid of one, please advise as to price, condition and location (I am in the
By
bobkrassa
·
#189127
·
|
Re: TM500 a reasonable choice for my novice needs?
I have a DM5010 I am not using, and would be interested is selling or trading. I have changed the battery and cleaned up very minor leakage (no repair to the boards if I recall). It does need to be
By
Joe Laffey
·
#189126
·
|
Re: 7723
Yes, I¡¯ve replaced them quite often in my equipment, just for good measure. But I can¡¯t recall seeing one in the 7723. I¡¯ll open it up this afternoon.
By
Stephen
·
#189125
·
|
Re: 7704A, good deal?
Ok. Thanks all. I will review as much material as I can. Happy to know that the unit is working as it should, and at some point it was properly calibrated, has the cal seals intact, albeit from 20
By
Stephen
·
#189124
·
|
Re: 2465B restoration, what manual to use?
Dear Leo, bonjour, bravo pour le achat ! I have had 2465, 2465A and 2467B back to early 1990s. great scopes with many interesting options, most need PSU recapping and in B version A5 SMD CAP
By
Jean-Paul
·
#189123
·
|
Re: 2465B restoration, what manual to use?
Hi Leo, Indeed with Heerenveen, Guernsey and Japanese production there is no comparison listing as far as I know. Board Numbers (e.g. 671-0965-05: A5 Controller Board) are more practical. With these
By
Egge Siert
·
#189122
·
|
Re: Looking for, ¡°TroubleShooting your TEK Oscilloscope Military Virsion¡±
Here's a link to a general manual from Tektronix, on diagnosing scopes. https://www.sphere.bc.ca/test/tek-parts/troubleshooting-scopes.pdf
By
Mart Bosma
·
#189121
·
|
Re: Looking for, ¡°TroubleShooting your TEK Oscilloscope Military Virsion¡±
General TEK "Troubleshooting your TEK osciloscope " manual: download at: https://www.sphere.bc.ca/test/tek-parts/troubleshooting-scopes.pdf
By
Mart Bosma
·
#189120
·
|
Re: TEKTRONIX AM700
I've also an AM700 that works quite well, luckily. The seller even brought it to my home to make sure no damage!! Only problem is a strange behaviour in monitor mode, but I never use it. Have a scope
By
Martin
·
#189119
·
|
Re: Looking for, ¡°TroubleShooting your TEK Oscilloscope Military Virsion¡±
Hi Andrew, if you send me a PM to mgrbosma@... I can send this manual to you via We Transfer. However, It will be only from Tuesday 28 December 2021 onwards, unless you can respond within the next
By
Redguuz
·
#189118
·
|
Re: Unable to calibrate Tek 177 fixture
Excellent, the calibration on the 577 should converge now. Looking for good news. Zen
By
Zentronics42@...
·
#189117
·
|
Re: TM500 a reasonable choice for my novice needs?
If anyone has any that are toast (DM5010) let me know I would be interested. Uncalibrated is fine. Zen
By
Zentronics42@...
·
#189116
·
|
Re: New 465 issue I posted a video
So what's going on when you get the scope into X-Y mode? The screen lights up like a storage scope with the intensity up too high (the whole screen glows an even bright green). What we expect in X-Y
By
Jeff Dutky
·
#189115
·
|
Need a time/div knob for SC504
Picked up an SC504 (TM500 80MHz dual-trace scope). It had been dropped on the knobs. The main problem was in the time/div switch area. Both the Var and Time/dir knobs were shattered and mostly
By
Cliff Carrie
·
#189114
·
|
File Notifications
#file-notice
The following files have been uploaded to the Files area of the [email protected] group. * /TEK 465B & DM44 Instruction.pdf ( /g/TekScopes/files/TEK 465B & DM44 Instruction.pdf )
By
[email protected] Notification <noreply@...>
·
#189113
·
|
Re: New 465 issue I posted a video
Interesting that the screen un-blanks and lights up when you set the sweep speed to X-Y. This mode causes the Z-Azis logic to unblank. See if you can find out why it's (almost) always blanked. I
By
DaveH52
·
#189112
·
|
Re: Patch cable for 7S12 015-1017-01 (750 pS)
Correct. Precision of delay time in cable between pulser and sampler isn't important. Raymond
By
Raymond Domp Frank
·