Re: Tektronix 465
If anyone needs a part let me know. Barry I could use the pots that deal with triggering and horizontal control their plastic knobs, A7 and A8 trigger boards. If you want contact me at.
By Craig Cramb · #207815 ·
DC balance pots on 575 curve tracer
Hi John : What a good answer to my question, I hope you don¡¯t mind my response to your personal mail. I did not mention that I have JFETs instead of a matching pair of 12au6s in both
By Anita Abranovic · #207814 ·
Re: Tektronix 465
Barry, One is what I need. I am in the states on the east coast. Thanks. I am considering the multiplier also as a spare for my plain and B version. Mark
By Mark Vincent · #207813 ·
Re: Tektronix 465
The one that I have is in excellent condition. Are you in the united states? Can you use just one? Barry
By Barry Breaux · #207812 ·
Re: Tektronix 465
Hi Mark, I used one of them. I cut the clear plastic time mark rings off and replaced it with one that had a broken knob. Great fix! I seem to be better at the hardware restoration than the circuit
By Barry Breaux · #207811 ·
Re: Solder - Tin/Silver or Tin/Lead/Silver?
So did the first Tek portable solid state 'scopes beginning in 1966, which also used the ceramic strips. When I bought my Tek 453 about 1994 the roll was missing, but I already owned a spool of
By Dale H. Cook · #207810 ·
Re: DC balance pot on 575 curve tracer
Not sure if this problem is on the vertical or horizontal amp, but the trouble-shooting should be similar. First, the balance pot: on early s/n's this was 5k, changed to 10k on s/n 6630 up . 100k
By John Sykes · #207809 ·
Re: Tektronix 454A Oscilloscope No Trace but Beam Finder works fine?
Yes that has been the only one so far. As soon as I replaced it, the ¡®scope then worked fine so I can say for sure it ¡®s bad.
By Jeffrey Wang · #207808 ·
Re: Tektronix 465
Barry, I can use the v/div knobs. Mark
By Mark Vincent · #207807 ·
Re: Tektronix 454A Oscilloscope No Trace but Beam Finder works fine?
Hi Adam, Yes, I had the wrong post in my brain buffer. Thanks for re-aligning my neurons! -- Cheers, Tom -- Prof. Thomas H. Lee Allen Ctr., Rm. 205 420 Via Palou Mall Stanford University Stanford,
By Tom Lee · #207806 ·
Re: New method for 7K SMPS problem diagnosis
Well, at least it's alive. The power supplies are all up and it has a sharp bright blue trace, but obvious problems in the vertical system and readout so far. I'll have to work on it hopefully
By ed breya · #207805 ·
Re: Tektronix 454A Oscilloscope No Trace but Beam Finder works fine?
Tom, I had that same thought when seeing Barry Breaux's post this morning about a 465 he's parting out. I wonder if that's the message you're thinking
By Adam R. Maxwell · #207804 ·
Re: Tektronix 454A Oscilloscope No Trace but Beam Finder works fine?
Hi Jeff, How did you determine that those transistors were bad? If you used one of those do-it-all component testers, check again with a DMM or curve tracer. The testers can break down the
By Tom Lee · #207803 ·
Re: Tektronix 454A Oscilloscope No Trace but Beam Finder works fine?
Perfect! I'll order some of these transistors. Thanks for sharing the info, Mark! Jeffrey
By Jeffrey Wang · #207802 ·
Re: Tektronix 454A Oscilloscope No Trace but Beam Finder works fine?
Jeffrey, A KSP10BU will replace the bad transistor. The pinout is BEC. This transistor will replace others as well. The 0367 is an example. Mark
By Mark Vincent · #207801 ·
DC balance pot on 575 curve tracer
Hi everyone, My 575 curve tracer¡¯s DC balance on front panel won¡¯t calibrate properly. I am following the calibration procedures in the manual. The dot won¡¯t center, with the pot range
By Anita Abranovic · #207800 ·
Re: Tektronix 454A Oscilloscope No Trace but Beam Finder works fine?
I'm glad to share that I've successfully identified the culprit: transistor Q364. I tracked it down by shorting the bases of transistors on the upper and lower rails, block by block, starting with the
By Jeffrey Wang · #207799 ·
New method for 7K SMPS problem diagnosis
I'm on my last 7K repair project, another 7904. This one has been a PITA with a failure inside the power supply. I had gotten it down to suspecting something in the HV supply, and set it aside a while
By ed breya · #207798 ·
Re: Quarter-turn panel fasteners
They¡¯re not in fact Dzus (yes sorry my incorrect prior spelling) - as those indeed rely on a fixed receptacle, whereas the ones on the 130 have ¡®ears¡¯ that when rotated slide being the edge of
By Richard Kelly · #207797 ·
Re: 80E04 sampling module - fair price?
Well, those are expensive birds, mostly because of the hybrid frontends. But you still can buy a non-functional one for $200 - $500. A typical 8x00 series plugin contains a hybrid frontend where the