Re: 2465B Parametric Freq Measurement Error
Hi Chuck, The parametric functions do not work on one of my 2445Bs, the one you didn't calibrate.? It also doesn't sync on signal on start-up but does work well manually.? I chased this around? on
By
John Ferguson
·
#156533
·
|
2465 repair attempt with (horizontal?) issues, help needed
Hi all, I got (yet another for my collection) 2465, it was stated it had problems before I got it, so no problem there. What have I done so far: Recapped the Power Supply, cleaned the Siemens fan and
By
satbeginner
·
#156532
·
|
Re: 2465B Parametric Freq Measurement Error
Hi Chuck, Nope. I found others for sale, but these were cheaper. Tom
By
Tom B
·
#156531
·
|
Re: 2465B Parametric Freq Measurement Error
Exactly! Have you tried their product? -Chuck Harris Tom B wrote:
By
Chuck Harris <cfharris@...>
·
#156530
·
|
Re: 475A with High +110 rail
On the 474A L.V. schematic it shows the expected voltage at the emitter of Q1496 as being 135.6 volts, which is quite close to your 134.66 reading at your +110 test point. It shows the expected
By
tom jobe <tomjobe@...>
·
#156529
·
|
Re: 2465B Parametric Freq Measurement Error
Hi Chuck, Like this: http://smallbear-electronics.mybigcommerce.com/nut-starter/ Tom
By
Tom B
·
#156528
·
|
Re: My TDR Evaluation of the SG503 012-0482-00 Cable has been uploaded
The document says: "The speed of light in a vacuum is 224844343.5 m/Sec= 0.2248m/nSec. " I guess Dennis already used some kind of velocity factor here. But this makes his following derivation invalid:
By
Albert Otten
·
#156527
·
|
Re: 2465B Parametric Freq Measurement Error
All members of the 2465 family use interchangeable trigger hybrids. To remove them, remove the four nuts at the corners of the module. Tektronix considered them all to be "selected"... which I think
By
Chuck Harris <cfharris@...>
·
#156526
·
|
Re: 2465B Parametric Freq Measurement Error
of course, but only cal03. -Chuck Harris joe@... wrote:
By
Chuck Harris <cfharris@...>
·
#156525
·
|
Re: My TDR Evaluation of the SG503 012-0482-00 Cable has been uploaded
Where does it show the speed of light in a vacuum? The TDR should be calibrated to the speed of light (electricity) in the cable. For 50 Ohm cable its about 66% of c. Varies with the impedance of the
By
Richard Knoppow
·
#156524
·
|
Re: My TDR Evaluation of the SG503 012-0482-00 Cable has been uploaded
Interesting stuff Dennis! I have to look at it in more detail. I consider repeating these tests since I have both Tek cables, though I don't have quality SMA-BNC adapters. Most remarkable is the slow
By
Albert Otten
·
#156523
·
|
Re: My TDR Evaluation of the SG503 012-0482-00 Cable has been uploaded
Very timely: this weekend I picked up a Tek 1502B, and it came with a 012-0482-00 cable and a 011-0123-00 BNC 50ohm terminator. Apart from that I only have "generic" connectors and terminators, of
By
Tom Gardner
·
#156522
·
|
Re: My TDR Evaluation of the SG503 012-0482-00 Cable has been uploaded
I?m going to solder a 1m RG223 cable for my SG503 so this is interesting stuff for me. Nice detailed piece of work Dennis, thanx!!
By
tek_547
·
#156521
·
|
Re: 475A with High +110 rail
Michael- I also would check the eb voltages? of Q1496 and Q1497 make sure nothing strange and xstrs are operating in their proper regions. I would then take a hard look at CR1489 ( protection ec
By
Ren¨¦e
·
#156520
·
|
Re: My TDR Evaluation of the SG503 012-0482-00 Cable has been uploaded
Those are interesting measurements Dennis. And particularly interesting that although the Pomona/Belden the impedance is not 50 ohms, although the variation seems to be very low. And it will be more
By
Craig Sawyers <c.sawyers@...>
·
#156519
·
|
475A with High +110 rail
I have searched for a previous thread that was referred to in a post about a "high" 110 voltage rail on a 475 from back in 2012. I failed to find that post or any other applicable answer, perhaps I am
By
Mlynch001
·
#156518
·
|
Re: 2465B Parametric Freq Measurement Error
Is my Tektronix 2465 DMS using the same part number or do I need a different one? Where would I find more information how to perform the replacement? Thanks. Tony
By
Tony Fleming
·
#156517
·
|
Re: 2465B Parametric Freq Measurement Error
If I replace the trigger hybrid, do I have to do the whole calibration again? Joseph Suste
By
joe@...
·
#156516
·
|
Re: 2465B Parametric Freq Measurement Error
The parametric measurements use the trigger hybrid extensively, and their performance is directly related to how well that hybrid performs. Some are better than others. -Chuck Harris joe@...
By
Chuck Harris <cfharris@...>
·
#156515
·
|
Re: 2246 no display/odd behavior
Take note of where the grid bias R2719 is currently set by following the setup in the manual. You will do this in XY mode. See if you can get a dot displayed. I agree that all the power supply rails