¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Resurrecting a 475 - Request for Guidance
I have recently become the proud owner of a 475 that I found abandoned at the side of a road! Other than a couple dents in the casing, it appears to be in pretty good condition. After replacing the
By JR · #150426 ·
Re: Acqusition board available, cheap
I would be interested
By Miles Paulson · #150425 ·
Re: Scope
Hi Harvey, Thanks for your email. It was very helpful. I was working with the scope for a while, turning it off and on a few times, and finally the screen came up. I suspect that since the scope
By Thomas Dodge · #150424 ·
Re: 464
Hi Gypsy, The question is too open-ended. It is expected that you would ask it and then list the 'five' basic tests you ran and their results. The 464 S/M itself has a Troubleshooting chapter for you
By Jon Batters · #150423 ·
Acqusition board available, cheap
I have a surplus acquisition board, P/N 679-4774-02 (from the label) or G9F-2841-00 (from the top copper layer). It was, as far as I know, working when pulled out of its host TDS520. The 'scope itself
By Bruce Lane · #150422 ·
Re: 2465B Replace Aluminum Electrolytics with Tantalum
I don't share your disdain for tantalum electrolytic capacitors.? Their dramatic failure modes to happen when they are operated near their rated voltage.? For this reason, I de-rate their voltage
By machineguy59 · #150421 ·
Re: 2465B Replace Aluminum Electrolytics with Tantalum
So you replaced parts who's current main failure mode is less capacitance with a part who's known normal failure modes are burns up in flames taking out the PCB or short circuit taking out the parts
By Hawker · #150420 ·
DM501A AC range calibration
Howdy all. Was trying to calibrate a DM501A this weekend. DC volts calibrated with no issues however AC volts and dBmV did not. In both cases I ran out of pot room just a tad before I had it in
By Hawker · #150419 ·
Re: 2465B Replace Aluminum Electrolytics with Tantalum
By Bert Haskins · #150418 ·
Re: Scope
On Sat, 11 Aug 2018 20:31:33 -0700, you wrote: All the lights ought to come on, then the power up sequence starts. You should hear relays clicking, and you should see different lights on the front
By Harvey White · #150417 ·
FYI: Tektronix 7S12+S6+S52+S53+S54 TDR/Sampler - Outstanding Condition!
https://www.ebay.com/itm/132740408593?ul_noapp=true No affiliation.
By Ancel · #150416 ·
Re: scanned: 545B and 561 Instrument Reference Books
A big THANX for all the effort !
By tek_547 · #150415 ·
Re: Scope
On Sat, Aug 11, 2018 at 8:27 PM Thomas Dodge <tdodge2404@...> wrote: > Hi, > My name is Tom, and I haven't sent any emails in a while. I just bought a > Tektronix TDS 648A scope. I plugged it in
By Thomas Dodge · #150414 ·
Re: No trace on 556 :(
Only to be careful with the high voltage and the complex reassembly process. My replacement transformers were layer wound but the originals are pie (universal) wound. Chuck Harris on this group has
By Morris Odell · #150413 ·
Re: SG 504 leveled sine wave generator.
Took the chance to recal. the unit using better precision gear than specified in the manual. Improved the 6Mhz reference accuracy to -0.06dBm vs -0.12dBm with the R270 & R280 amplitude adjustments.
By Ancel · #150412 ·
Re: 2465B Replace Aluminum Electrolytics with Tantalum
And me 108 years.? That is if my electrolyics don't leak out.
By machineguy59 · #150411 ·
SG 504 leveled sine wave generator.
Hi y'all: Was doing some calibrations on some precision, stub tuned (+/- 0.10dBm @ 4Vpp, full range) leveling heads over the past couple of weeks for the EBAY sale listing that I put up occasionally
By Ancel · #150410 ·
Re: 2465B Replace Aluminum Electrolytics with Tantalum
Lets see that would make me 107 Years Young. Sounds like you did a good job.?Leon Robinson ?? K5JLR Political Correctness is a Political Disease. To: [email protected] Sent: Saturday, August 11,
By Leon Robinson · #150409 ·
2465B Replace Aluminum Electrolytics with Tantalum
See this photo album /g/TekScopes/album?id=66462 for my recent repairs on a 2465B. This 2465B had modest corrosion on the A5 board from leaking aluminum electrolytic capacitors. On
By machineguy59 · #150408 ·
Re: 2215A LVPS repair
On Sat, Aug 11, 2018 at 05:29 PM, tom jobe wrote: > > Hi Leo, > Yesterday I found the Fluke thermocouple and did some tests on a 2215A. > First I disconnected the optional fan, then let the scope run
By satbeginner · #150407 ·