Re: A little off Topic, SG504 Output Head
Situation normal. Liquidators shove the equipment in one pile, and anything they think is a "lead" they shove in another (or worse, in the dumpster). Hah! Good luck for the "reasonable price"! They
By Craig Sawyers <c.sawyers@...> · #34791 ·
DM44 badly behaved
I have just accepted a Tek475A plus DM44 for the school electronics club. However, the DM44 has some problem with the display multiplex. Does anyone have aschematic diagram they can send to me please?
By Kelvin · #34790 ·
A little off Topic, SG504 Output Head
Hi: I bought a SG504 RF Generator on Ebay with NO Output Head. Anyone have a Source for one at a Reasonable Price? The Part Number is 015-0282-00. Also Looking for a 012 0482 00 50 ohm precision bnc
By kozey746 · #34789 ·
Manual for Tek 465M
Hello, We just acquired a couple of 465M's ( non working) and would love to get our hands on a schematic (or schematics) so we can get these repaired. They appear to have power supply issues, as we
By Ashley <Ashley40@...> · #34788 ·
2465B fails freq measurement?
Connected to a nice clean sine wave but pressing 'measure' 'freq' reports signal is noisy or not periodic. Any ideas? Scope works great otherwise. Thanks, David.
By David Woodhead · #34787 ·
Trace Problem 2465 scope
I Havve just aquired a 2465 300MHz scope. When i first power up all tests pass, but the crt shows a very jagged display (almost as if you were seeing noise) The display notations of sweep time and
By suttonri · #34786 ·
Re: Massachusetts surplus
There is a decent surplus store in southern New Hampshire. Just a block from I-93. http://esssurplus.com/index.html They have a limited selection of older test equipment, and lots of interesting other
By ebayatessnh · #34785 ·
free TM506 in NYC
Gentlemen, I have a TM506 that works but needs new filter capacitors. The DC supply gets a lot of ripple when the TM506 is full of plug-ins, with just a couple of plug-ins it is fine. If this is if
By Kurt <sipespresso@...> · #34784 ·
Everything should now be up!
OK... I believe I've got both web and FTP working now. Thanks to all for your patience, and special thanks to N5ZTW for spotting the fact that the web server had gone flooey. Happy tweaking.
By Bruce Lane · #34783 ·
Problems with web site
Well, I can't seem to win at the moment. I've got the FTP server working, but now I seem to have knocked the web server off the air. I'm working on it. Hope to have it up before too much longer.
By Bruce Lane · #34782 ·
Massachusetts surplus
Anybody know if there are any decent surplus stores left in MA? Like where they have Tek or HP gear? Now that I work there, figured I'd ask. Also looking for a local place I could buy (and pick up) a
By Peter Gottlieb <hpnpilot@...> · #34781 ·
Blue Feather FTP site is back!
Fellow techies, I'm happy to report (finally!) that the Blue Feather FTP site has been restored, and is now available as follows. Site name: ftp.bluefeathertech.com User ID: ftp Password: Anything you
By Bruce Lane · #34780 ·
Sony-TEK 308 service manual
Hi Group. Anyone that got a service manual for a Sony-Tek 308 data analyzer? With best regards Tomas Larsson TL Engineering & Consultants Engelbrektsgatan 121 SE 506 39 Bor?s Sweden +46 739 932 673
By Tomas <tomaslarssonse@...> · #34779 ·
323 & 475A Manuals available
AVAILABLE: original Tek manuals Instruction manual, pn 070-0750-00 for 323 Instruction manual, pn 070-2163-00 for 475A Service manual, pn 070-2162-0000 for 475A Available for cost of packing and
By w5bi <w5bi@...> · #34778 ·
Re: CRT Phosphors
<w7ni@...> wrote: I of it, so considered was see in a was a would not P2 or P31 of very
By Joe Rooney <ikerooney@...> · #34777 ·
CRT Phosphors
I wrote the following stuff about phosphors in response to question I received. I thought some of you guys might get some new info out of it, so here it is. Stan CRT Phosphors: Back in the early 60's
By Stan & Patricia Griffiths · #34776 ·
Re: Tek 545 Hint
Thanks for the tip, Ed. Always corroborate. Tek used specific color-coded wires for the power supply lines; if "225" doesn't point to red-red-green, the label is wrong. Or the wire. Dave Wise
By Dave Wise · #34775 ·
Tek 545 Hint
Hi, Gang I have a 545 (no suffix) scope, and recently had to do some trouble-shooting. One hint: when measuring d.c. voltages along the ceramic terminal strip which has the voltages labeled on the
By k2orsfan · #34774 ·
Re: Need Tek 442 Manual
I?purchased mine at Qservice ? qservice@... ? Bob
By Robert Simpson · #34773 ·
Re: 2465 saga continues...............
If the surge arrestors get a voltage higher than 230V then they are going to blow the fuse. Check to see what voltage the surge arrestors get to before the fuse blows by ramping up the input voltage
By cmbath · #34772 ·