Re: 7904 pre-260000 PSU crackling
When I first got this 7904 it has been stored unused for years. I turned it on and the scope, with some plug-ins, entered tick-mode. I spent months trying to figure out what was wrong to no avail. I
By G?ran Krusell · #208050 ·
Tek Type 130 L-C Meter - confirming the meter capacitor 'error'...?
I read Alan Hampel's article on restoration of the above. He asserts that "Surprisingly, electrolytics C99 (5?F) and C100 (25?F), factory originals, were installed backwards! Not surprisingly,
By Richard Kelly · #208049 ·
Re: Tek 465M saga
Hi, I read many of your posts on the 465m blowing HVPS fuse...I actually acquired a 465m looking almost brand new with the saga of the fuse blowing.. I just have one question, what is the voltage
By richard ramacieri · #208048 ·
Re: 7904 pre-260000 PSU crackling
Thanks for the advice. Re. the nick in the HV lead, I have not used dielectric grease before, does it set or would I need some particular variant for the voltages involved? Also, would a better
By James · #208047 ·
465M with option 93
I have a recently acquired 465M with option 93. I can't seem to find and info on what that option is. Does anyone here know?
By whipaway · #208046 ·
Re: Tek 7704 scope cover
Evan Just post them. Everyone and is dog expects to have to modify 3D printer files. TIA EJP
By EJP · #208045 ·
Re: Tek 7704 scope cover
Hi Dave, I know it seems that simple but I put some internal reinforcement beams across the top of the bays where the plugins go. I also did one over the row of controls over that and another L
By evan foss · #208044 ·
Re: Faulty 2465B
Well, whaddya know. I found this while randomly searching for 2465B problems: https://bradthx.blogspot.com/2017/08/tektronix-2465b-repair-part-ii.html The description of the triggering problem was
By Keith · #208043 ·
Re: 7904 pre-260000 PSU crackling
Jon, Just to prevent a possible misunderstanding: I wasn¡¯t talking about the ultor but the white two-part connector somewhere near the middle of the HV lead, where the (usually) red lead enters
By Raymond Domp Frank · #208042 ·
Re: 7904 pre-260000 PSU crackling
Raymond the 21-24 KV CRT Ultor is polyethylene as is,the molded Alden connector. Indeed any nicks or splitting of the cable will cause arcs or corona to the nearby grounds og the ch?ssis , doghouse
By Jean-Paul · #208041 ·
Re: 7904 pre-260000 PSU crackling
I guess something to realize is that an air gap from the HV lead core to the outside of the insulation isn't enough to prevent arcing or even flash over; The dielectric strength of air is far less
By Raymond Domp Frank · #208040 ·
FS Tektronix 575 w/ Mod 122C
Cross posting from Equipment For Sale group https://test-equipment-for-sale-wanted-or-exchange.groups.io/g/main/topic/fs_tektronix_575_w_mod_122c/110600766 Clean insde & out. The selenium stack was
By Charlie · #208039 ·
FS Tektronix 577 D1 / 177 w/ Option 10
Cross posting this from the Equipment For Sale group https://test-equipment-for-sale-wanted-or-exchange.groups.io/g/main/topic/fs_tektronix_577_d1_177_w/110601072 Clean inside and out. Serial #s 577:
By Charlie · #208038 ·
Re: Faulty 2465B
It affects all channels in the same way. Hence the thought that it's maybe an issue with U500? Keith
By Keith · #208037 ·
Re: Faulty 2465B
Rebonjour Does the trigger issue, affect all 4 ch and line or only certain channels? Trigger path is from vert amps and multiplex IC. Use the self test, one og the tests or exer is for
By Jean-Paul · #208036 ·
Re: 7904 pre-260000 PSU crackling
Hello, I had a similar crackling and hissing problem with my 7904 years ago. It turned out to be the voltage multiplier U1615, internal arcing. The only visible indication of something being wrong was
By G?ran Krusell · #208035 ·
Re: 7904 pre-260000 PSU crackling
Thanks for the reply Jon, The nick on the HV cable is about half way along from the dog hole to the connector, visible on the third image. If I don't need to mess with the transformer I won't, it's
By James · #208034 ·
Re: Faulty 2465B
Merci Jean-Paul Probing the TGA signal from pin 18 of U500, the triggering waveform there is as I see it on the screen i.e. intermittent. So it looks like U500 or circuitry before it in the trigger
By Keith · #208033 ·
Re: 80E04 sampling module - fair price?
Thanks for your suggestion, today I received a secondhand 80e02 in good condition for an acceptable price ?
By Wevie · #208032 ·
Re: Faulty 2465B
Keith bravo for your work on NV Ram, beware of Chinese knock-off and old date code parts. Use machine pin socket Full cal is needed after RAM replacement See service manual and proper test
By Jean-Paul · #208031 ·