Trace Problem 2465 scope
I Havve just aquired a 2465 300MHz scope. When i first power up all tests pass, but the crt shows a very jagged display (almost as if you were seeing noise) The display notations of sweep time and
By
suttonri
·
#34786
·
|
Re: Massachusetts surplus
There is a decent surplus store in southern New Hampshire. Just a block from I-93. http://esssurplus.com/index.html They have a limited selection of older test equipment, and lots of interesting other
By
ebayatessnh
·
#34785
·
|
free TM506 in NYC
Gentlemen, I have a TM506 that works but needs new filter capacitors. The DC supply gets a lot of ripple when the TM506 is full of plug-ins, with just a couple of plug-ins it is fine. If this is if
By
Kurt <sipespresso@...>
·
#34784
·
|
Everything should now be up!
OK... I believe I've got both web and FTP working now. Thanks to all for your patience, and special thanks to N5ZTW for spotting the fact that the web server had gone flooey. Happy tweaking.
By
Bruce Lane
·
#34783
·
|
Problems with web site
Well, I can't seem to win at the moment. I've got the FTP server working, but now I seem to have knocked the web server off the air. I'm working on it. Hope to have it up before too much longer.
By
Bruce Lane
·
#34782
·
|
Massachusetts surplus
Anybody know if there are any decent surplus stores left in MA? Like where they have Tek or HP gear? Now that I work there, figured I'd ask. Also looking for a local place I could buy (and pick up) a
By
Peter Gottlieb <hpnpilot@...>
·
#34781
·
|
Blue Feather FTP site is back!
Fellow techies, I'm happy to report (finally!) that the Blue Feather FTP site has been restored, and is now available as follows. Site name: ftp.bluefeathertech.com User ID: ftp Password: Anything you
By
Bruce Lane
·
#34780
·
|
Sony-TEK 308 service manual
Hi Group. Anyone that got a service manual for a Sony-Tek 308 data analyzer? With best regards Tomas Larsson TL Engineering & Consultants Engelbrektsgatan 121 SE 506 39 Bor?s Sweden +46 739 932 673
By
Tomas <tomaslarssonse@...>
·
#34779
·
|
323 & 475A Manuals available
AVAILABLE: original Tek manuals Instruction manual, pn 070-0750-00 for 323 Instruction manual, pn 070-2163-00 for 475A Service manual, pn 070-2162-0000 for 475A Available for cost of packing and
By
w5bi <w5bi@...>
·
#34778
·
|
Re: CRT Phosphors
<w7ni@...> wrote: I of it, so considered was see in a was a would not P2 or P31 of very
By
Joe Rooney <ikerooney@...>
·
#34777
·
|
CRT Phosphors
I wrote the following stuff about phosphors in response to question I received. I thought some of you guys might get some new info out of it, so here it is. Stan CRT Phosphors: Back in the early 60's
By
Stan & Patricia Griffiths
·
#34776
·
|
Re: Tek 545 Hint
Thanks for the tip, Ed. Always corroborate. Tek used specific color-coded wires for the power supply lines; if "225" doesn't point to red-red-green, the label is wrong. Or the wire. Dave Wise
By
Dave Wise
·
#34775
·
|
Tek 545 Hint
Hi, Gang I have a 545 (no suffix) scope, and recently had to do some trouble-shooting. One hint: when measuring d.c. voltages along the ceramic terminal strip which has the voltages labeled on the
By
k2orsfan
·
#34774
·
|
Re: Need Tek 442 Manual
I?purchased mine at Qservice ? qservice@... ? Bob
By
Robert Simpson
·
#34773
·
|
Re: 2465 saga continues...............
If the surge arrestors get a voltage higher than 230V then they are going to blow the fuse. Check to see what voltage the surge arrestors get to before the fuse blows by ramping up the input voltage
By
cmbath
·
#34772
·
|
Need Tek 442 Manual
Hi everyone I've looked everywhere for a 442 manual and come up empty. Any ideas? Thanks.. Tad WA1FQO
By
Tad
·
#34771
·
|
Re: 2215 Problem
Let me guess, the capacitor was a RIFA cap? Every Tek scope that I have seen and have checked the X class suppression capacitors on has at least shown fracture marks in the epoxy coating if it was of
By
cmbath
·
#34770
·
|
Re: SG5030 behavior
Hi Howard, mine does not do this, starts up perfectly each time. So something is amiss here. Mit freundlichen Gr¨¹?en, / Best regards, Florian Diederichsen
By
Florian Diederichsen <florian.diederichsen@...>
·
#34769
·
|
2465 saga continues...............
So far I have replaced the main PSU capacitors plus the bridge rectifier and the DC supply started to come up -- then the mains fuse blew. After changing the fuse I tried to power it up using a
By
oldtestgear <philip.parsons@...>
·
#34768
·
|
Re: SG5030 behavior
The heatgun and cooling spray method is not very pactical in this instance because it is very difficult to run this unit when it is disassembled. Some of the boards have machined aluminum heatsinks
By
victor.silva
·
#34767
·
|