Re: P6015A HV Probe: Applications?
This needs to be put in context. The peak of ozone depelting CFC's was in the mid 80's, when R12 was used in all domestic and automotive refrigerators worldwide. In addition, other CFC's were used as
By
Craig Sawyers <c.sawyers@...>
·
#34647
·
|
Thanks to all (P6015A)
Thanks to all who provided insight on the P6015A HV probe. After due consideration, and considering it's one of the newer type that uses a no-refill-required silicone compound instead of fluorocarbon
By
Bruce Lane
·
#34646
·
|
Re: P6015A HV Probe: Applications?
If you can use it with a DMM it gives a very high input resistance (probably about a Gigohm?) and with the sensitivity of even basic DMMs will measure 200 volts full scale with resolution down to 0.1
By
Don Black <jeans@...>
·
#34645
·
|
TDS380 CH1 Module
Does anyone out there have a front end channel module for a TDS380 scope??? The schematic shows a AT206/B2565 module. It's a hybrid part. The input channel will measure -5.3vdc on the most sensititive
By
normanshanks <normanshanks@...>
·
#34644
·
|
FREE PART!
Tek group I have a transformer pn 120-169 Recollection is that it was changed out of a small scope 30 or so years ago and didn't fix the problem. Don't remember what scope. This transformer is potted
By
Paul Kraemer <elespe@...>
·
#34643
·
|
Re: P6015A HV Probe: Applications?
Freon, one of the Ozone layer destroying gasses. There were two of the P6015 series probes, one designed for 25kV and the other designed for 40kV. I say designed because I know from personal
By
Geoff Blake <geoff@...>
·
#34642
·
|
Re: More Tek 494P GPIB help needed
If the talk-only and listen-only switches are both off, and address 0 is reported by the analyzer even though the address switches are set to (say) address 31, then I'd look at the other end of the
By
John Miles <jmiles@...>
·
#34641
·
|
Re: P6015A HV Probe: Applications?
Hi ALL, Actually I have several P-6015A HV probes. The older ones came with a can of some Fluorocarbon solution which could be put into the probe allowing for measurement of even higher voltages. I
By
ken chalfant
·
#34639
·
|
Re: P6015A HV Probe: Applications?
The ones with the freon fill are P6015s, and the newer ones with the silicone gel fill are P6015As. Without freon, the P6015s are rated to 13kV. Otherwise, the rating is 20kVDC/40kV peak. It's 75MHz,
By
David DiGiacomo
·
#34640
·
|
Re: P6015A HV Probe: Applications?
Hi, Chuck, * REPLY SEPARATOR * <snippage> Thank you. I thought about that after pressing 'send.' ;-) You're right. Other than possibly developing a Tesla coil, as Dave suggested, I
By
Bruce Lane
·
#34638
·
|
Re: P6015A HV Probe: Applications?
I used one back in the late '70s while developing a small pulsed carbon dioxide laser. Bit of a chewing gum and string affair. This used a high charging voltage (10kV or so IIRC) from an HV power
By
Craig Sawyers <c.sawyers@...>
·
#34637
·
|
P6015A HV Probe: Applications?
Fellow tekkies, I was cleaning up today, and came across an item I picked up from Boeing Surplus some years ago: A P6015A high-voltage probe in just about mint condition. I have vague memories of
By
Bruce Lane
·
#34636
·
|
Re: More Tek 494P GPIB help needed
Hi, I remember now that in the late 90's I'd a similar problem with my 496P. I was using the Tektronix software GRASP and I remember well that I was obliged to leave all the back panel switch to OFF
By
Pierre-Fran?ois <pfmonet@...>
·
#34635
·
|
More Tek 494P GPIB help needed
Hi Thanks for all the helpful suggestions I received earlier but my Tek 494P spectrum analyzer GPIB still does not respond and I could use some help. I took the GPIB board out of the unit (fairly easy
By
John Pavelich
·
#34634
·
|
FS: 7603 manuals
7603 operators and service manuals, excellent condition, almost new. Shipped to your door lower 48 $30 postpaid. Thanks for the BW. Mike W2IY
By
devnull8it <devnull8it@...>
·
#34633
·
|
2445 vs 2465 scopes
After spending a lot of time messing around trying to get my 2465 working again without success, I am wondering what my options are. The 2445 works really well & triggers reliably beyond 200MHz. Can
By
oldtestgear <philip.parsons@...>
·
#34632
·
|
7CT1N failure
Greetings, ? I just recently got my 7CT1N working with my 7B70 and a 7A26 in my 7603. Yesterday I went to try it out with a new adapter and found that no trace is being generated. The dot can be
By
Jerry Massengale <jmassen418@...>
·
#34631
·
|
Re: selenium rectifiers in a 317
If you look at the BAMA and Kurt's different schematics of the 317 PS, the B+/plate supply?winding voltages are different.? The newer diode version is about 10 volts RMS less per winding.? The BAMA
By
Jim Reese
·
#34630
·
|
Re: Tektronix schematic question
Looks like the draft persons initials and the date. There are different intitals on some of the drawings in the 317 manual. ? Jim
By
Jim Reese
·
#34629
·
|
Tektronix schematic question
Hello Everyone, I tried posting this yesterday, but it did not show up on the Tekscopes message board... Would anyone know what "R.O.W." in the lower right corner of an older Tektronix schematic
By
tom jobe <tomjobe@...>
·
#34628
·
|